Table 5.
Parameters | Cutoff valuea | Sensitivity | Specificity | Accuracy | AUC | 95% CI |
---|---|---|---|---|---|---|
ADCmean | 1666.25 | 0.778 | 0.710 | 0.763 | 0.772 | 0.652–0.891 |
ADCmin | 649.50 | 0.667 | 0.742 | 0.684 | 0.737 | 0.618–0.856 |
ADCmax | 3531.00 | 0.484 | 0.833 | 0.563 | 0.656 | 0.523–0.789 |
ADC5% | 1213.50 | 0.722 | 0.839 | 0.748 | 0.785 | 0.663–0.907 |
ADC10% | 1293.00 | 0.722 | 0.806 | 0.741 | 0.794 | 0.677–0.911 |
ADC25% | 1424.50 | 0.778 | 0.258 | 0.661 | 0.791 | 0.673–0.909 |
ADC50% | 1539.00 | 0.889 | 0.597 | 0.823 | 0.776 | 0.662–0.891 |
ADC75% | 1842.50 | 0.778 | 0.661 | 0.752 | 0.747 | 0.627–0.867 |
ADC90% | 2171.50 | 0.778 | 0.710 | 0.763 | 0.732 | 0.606–0.858 |
ADC apparent diffusion coefficient, AUC area under the receiver operating characteristic curve
athe cutoff values of the ADC histogram parameters were calculated by using the Youden index; CI, confidence interval