Abstract
Objective
Determine whether the SpO2/FiO2 ratio correlates with the PaO2/FiO2 ratio in burned children with smoke inhalation injury (SII), with the goal of understanding if the SpO2/FiO2 ratio can serve as a surrogate for the PaO2/FiO2 ratio for the diagnosis of acute respiratory distress syndrome (ARDS).
Design
Retrospective chart review.
Setting
Shriners Hospitals for Children - Galveston.
Patients
All burned children with SII who were admitted from 1996 to 2014 and had simultaneously obtained SpO2, FiO2, and PaO2 measurements.
Interventions
None.
Measurements and Main Results
Two hundred seventy-three patients (63% male, 8 ± 5 years, 53 ± 24% total body surface area burns) were analyzed. SpO2/FiO2 ratios were divided into 4 subgroups based on SpO2 values (≤ 100%, ≤ 98%, ≤ 95%, ≤ 92%). Significance was accepted at r2 > 0.81. The r2 (number of matches) was 0.66 (23,072) for ≤ 100%, 0.87 (18,932) for ≤ 98%, 0.89 (7,056) for ≤ 95%, and 0.93 (4,229) for ≤ 92%. In the subgroup of patients who developed ARDS, r2 was 0.65 (8,357) for ≤ 100%, 0.89 (7,578) for ≤ 98%, 0.89 (4,115) for ≤ 95%, and 0.91 (2,288) ≤ 92%.
Conclusions
PaO2/FiO2 and SpO2/FiO2 strongly correlate in burned children with SII, with a SpO2 of <92% providing the strongest correlation. Thus, SpO2/FiO2 ratio may be able to serve as surrogate for PaO2/FiO2, especially when titrating FiO2 to achieve a SpO2 of 90–95% (i.e., in the ARDS range).
Keywords: Acute respiratory distress syndrome, PALICC, acute lung injury, trauma, critical care
INTRODUCTION
Severe burn injury requires prolonged intensive care and treatment (1). Although mortality and morbidity due to burn injuries have decreased radically in the last decades, particular factors such as extreme age (>60 or < 2 years), a percentage of the total body surface area (TBSA) burned exceeding 60%, and presence of smoke inhalation injury (SII) still heavily influence survival rates (2) and outcomes (3, 4). The presence of SII is one of the 3 factors accounted for in the modified Baux score (5).
Acute lung injury (ALI) and acute respiratory distress syndrome (ARDS) are frequent sequelae of SII (6, 7), occur in up to 34% of patients with SII, and are associated with a high mortality of up to 43% (8, 9). In 1994, the American European Consensus Conference (AECC) described ALI and ARDS using the ratio of the partial pressure of oxygen in arterial blood (PaO2) to the fraction of inspired oxygen (FiO2; P/F)(10). Later, the Berlin ARDS definition defined 3 different grades or severity of ARDS: mild (P/F ratio, 200–300), moderate (P/F ratio, 100–200), and severe (P/F ratio, ≤ 100)(11). These guidelines were updated in 2015 for children by the Pediatric Acute Lung Injury Consensus Conference (PALICC). The resulting definition sets forth various criteria to define pediatric ARDS, including P/F ratio ≤ 300 or in cases where PaO2 is not available, a peripheral capillary oxygenation (SpO2)-to-FiO2 (S/F) ratio ≤ 264. In addition, criteria for grading severity in patients with invasive mechanical ventilated were introduced. These utilize the oxygenation index (OI), calculated with the FiO2, mean airway pressure, and PaO2 as well as the oxygenation saturation index (OSI), calculated with SpO2 (12).
According to this definition, ARDS diagnosis requires arterial blood gas samples, which can only be obtained intermittently and invasively or by continuous noninvasive pulse oximetry measurements. The S/F ratio has previously been shown to correlate with the P/F ratio in healthy patients as well as ICU patients with ALI or ARDS; however, there are no data for severely burned children with SII and the PALICC definition was developed without consideration of burned children (13–17). In this study, we investigated whether the S/F ratio correlates with P/F ratio in burned children with SII. We hypothesized that SpO2 could be used as a complementary measurement or surrogate parameter for PaO2, especially for SpO2 in the ARDS range (SpO2 90–95%), for preventive diagnosis and consequent earlier therapy.
MATERIALS AND METHODS
After approval of the Institutional Review Board (IRB 140361), a retrospective chart review was performed on medical records of all pediatric patients admitted to Shriners Hospitals for Children - Galveston between 1996 and 2014. A total of 932 patients with burns and SII (confirmed by direct bronchoscopy at our institution) were identified, and 28 were excluded because they were admitted more than 14 days after their injury. FiO2, SpO2, and PaO2 measurements recorded for these patients were taken at the Shriners Hospitals for Children - Galveston ICU (0 m in altitude) in a similar manner. All recorded values of FiO2, PaO2, and SpO2 were collected at the same time, with PaO2 values being separated from SpO2 and FiO2 measures by a maximum interval of 60 seconds, and were used to calculate the corresponding P/F ratio and S/F ratios. The corresponding P/F and S/F ratio values were then matched and used for correlation analysis. Of the 904 patients, 627 were excluded from the study owing to the inability to match P/F ratio and S/F ratio values. In the remaining 276 patients, all matches in which the PaO2 value was more than 100 mmHg (100 torr) and the simultaneous SpO2 value was less than 92% were excluded from the analysis. These data were excluded because PaO2 was considered more reliable than SpO2, given the retrospective study design, and because these matches were certainly influenced by temporary malposition of the pulse oximeter and could not be considered clinically trustworthy. The total number of removed matches was less than 1,000. Additionally, all matches during 100% oxygen therapy were excluded. This yielded a total of 273 patients for analysis. ARDS was diagnosed when patients met all American Burn Association Burn Quality Improvement Criteria as outlined in Table 1. These criteria differ from the PALICC criteria not considering special populations and the age of the patient and the timing of insult. All patients received a chest x-ray every morning while under mechanical ventilation. Demographic data were also collected from these patient’s records.
Table 1.
American Burn Association Burn Quality Improvement ARDS Criteria
|
|
|
ARDS, acute respiratory distress syndrome; P / F, PaO2 / FiO2; PEEP, positive end expiratory pressure.
Correlation between the P/F and S/F ratios was determined for the entire patient group as well for subgroups of patients who developed ARDS and patients who died of ARDS. The S/F ratios were divided into 4 subgroups, which were used to obtain 4 different correlations for each analysis. These groups were based on the different cutoff values of SpO2: 1) SpO2 to 100% of the S/F ratio; 2) SpO2 to 98% (<) of the S/F ratio; 3) SpO2 to 95% (<) of the S/F ratio; and 4) SpO2 to 92% (<) of the S/F ratio. These S/F ratio subgroups were stratified based on the sigmoidal characteristics of the oxygen-hemoglobin dissociation curve (i.e., to account for the fact that small increases in PaO2 dramatically increase SpO2 on the steep portion of the curve, and large changes in PaO2 minimally increase SpO2 on the plateau portion of the curve)(18).
Finally, the demographics of all patients were analyzed to identify factors influencing the development of ARDS.
Statistical Analysis
To determine the strength of the linear relationship between the P/F and S/F ratios, we used Pearson product-moment correlations to investigate relationships in groups of greater or less than 100%, 98%, 95%, and 92% SpO2 for all patients and patients with diagnosed ARDS. Goodness-of-fit of linear regressions were then developed for each group comparison. In determining characteristic differences in TBSA burned, length of stay, age, sex, admission time post burn between the patients that did or did not develop ARDS, an unpaired t-test was used. Ethnicity (White, Black, and Hispanic) differences between the groups that developed ARDS or not utilized a one-way analysis of variance. Within the specific group analysis, and all variables, data were determined to be appropriate for analysis without transformation of the data. PaO2, SpO2, and FiO2 matches with PaO2 above 100 mmHg and SpO2 under 92% were considered outliers and removed from the analysis. Data were analyzed with Graphpad Prism 6.0 (La Jolla, CA, USA) with significance set at p < 0.05. All data were reported as mean ± standard deviation (SD).
RESULTS
Of the 273 patients included in the analysis, 172 were male and 101 female. Patient demographics are summarized in Table 2. The predominant burn injury was flame injury (252/273; 92%), followed by electrical flame injury (7/273; 3%), contact burn (6/273; 2%), and other injury type (8/273; 3%). The length of ICU stay was 36 ± 36 days. Forty-seven patients (16%) developed ARDS, and 23 of the total 39 non-surviving patients (49%) had ARDS. Of these 23 patients, 16 (70%) had ARDS listed as the cause of death. FiO2 values ranged from 21% to 100%, PaO2 from 25 mmHg to 500 mmHg, and SpO2 from 40% to 100% of saturation.
Table 2.
Patient Characteristicsa
| Characteristic | Value |
|---|---|
| Gender, n | |
| Female | 101 |
| Male | 172 |
| Ethnicity, n (%) | |
| Hispanic | 175 (64) |
| Caucasian | 71 (26) |
| Black | 27 (10) |
| Age, years | 8 ± 5 |
| TBSA burned, % | 53 ± 24 |
| Admission post burn, days | 2 ± 3 |
ARDS, acute respiratory distress syndrome; SD, standard deviation; TBSA, total burn surface area.
Data expressed as mean ± SD unless noted otherwise.
For the entire study population, there were 23,072 matches with SpO2 ≤ 100% in 273 patients; 18,932 matches with SpO2 ≤ 98% in 269 patients; 7,056 matches with SpO2 ≤ 95% in 236 patients; and 4,229 matches with SpO2 ≤ 92% in 209 patients. The relationships between the P/F ratio and S/F ratio are summarized in Figure 1, while the r2 correlations and p-values were respectively: r2=0.66, p < 0.0001; r2=0.87, p < 0.0001; r2=0.89, p < 0.0001; and r2=0.93, p < 0.0001 (Fig. 1).
Figure 1.
Scatterplots for the entire patient database with the 4 different SpO2 subgroups. P/F = PaO2/FiO2, S/F = SpO2/FiO2.
For the ARDS patient group, there were 8,357 matches with SpO2 ≤100 in 40 patients; 7,578 matches with SpO2 ≤ 98 in 40 patients; 4,115 matches with SpO2 ≤ 95 in 39 patients; and 2,288 matches with SpO2 ≤ 92 in 38 patients. In this subgroup, the r2 correlation index was 0.65 for ≤ 100%, 0.89 for ≤ 98%, 0.89 for ≤ 95%, and 0.91 for ≤ 92% (Fig. 2).
Figure 2.
Scatterplots for the ARDS patient database with the 4 different SpO2 subgroups. P/F = PaO2/FiO2, S/F = SpO2/FiO2.
TBSA burned and length of stay were significantly higher in patients who developed ARDS (p < 0.0001 and p = 0.02, respectively), while age, sex, admission post burn, and race showed no interaction.
DISCUSSION
While others have reported the relationship between the S/F ratio and P/F ratio, we are unaware of previous comparisons in burn patients. We hypothesized that simultaneous calculations of the S/F ratio and P/F ratio are highly correlated in burned children with SII, especially during ARDS, when SpO2 and PaO2 levels are less than 100 mmHg (100 torr). Our data, in 273 patients, revealed strong correlations in all groups and extremely strong correlations when SpO2 was less than 95%.
The P/F ratio is used to diagnose and classify ARDS. Currently, oxygenation measurements for determining the PaO2 require an invasive sample of arterial blood. There are several limitations in obtaining this measurement. First, continuous PaO2 monitoring is not performed routinely, which is problematic since arterial blood saturation can rapidly change. Flori et al. showed that P/F ratio poorly correlates with the severity of pulmonary impairment in children (19). In many patients, an arterial line is not standard of care, especially in those that are not mechanically ventilated. This creates complications when arterial blood samples must be collected for every desired PaO2 measurement (20). Other measurement inconsistencies include patient positioning and endotracheal suctioning (21, 22). Finally, arterial blood sampling is increasingly scrutinized in ICUs due to cost, greater appreciation that excess blood sampling contributes to ICU anemia, and the general trend towards banked blood restriction (23, 24).
SpO2 readings are obtained through pulse oximetry devices, which have become standard monitors and widely used in the ICU (25). Continuous and noninvasive readings are major advantages of these devices. Nonetheless, pulse oximetry measurements can be affected by different variables. Dyshemoglobin states (carboxyhemoglobin and methemoglobin) can alter readings because they influence light absorption and accordingly, calibration of the pulse oximeter (26, 27). However, carboxyhemoglobin is unlikely to have significantly influenced SpO2 measurements in our study, as carboxyhemoglobin elimination primarily occurs during the first 48 hours after inhalation injury and we removed all matches occurring within this time. Additionally, we eliminated all matches occurring while patients received 100% oxygen therapy. Other factors influencing SpO2 measurements are states of impaired peripheral perfusion (25) and factors affecting the oxyhemoglobin dissociation curve (18). The sigmoidal shape of the curve affects the accuracy and reliability of the readings around its inflection point, where small changes in SpO2 correspond to big changes in PaO2. This effect has very limited influence in the presence of ARDS, in which the SpO2 range is around 90–95%. Our data are consistent with this, as greatest concordance occurred in this range. Severe anemia and use of dyes also influence the readings (28, 29); however, both red blood cell transfusion and the use of dyes are limited in our institution, making it unlikely that either factor significantly influenced the outcome. Skin pigmentation is another confounding factor (30). Lastly, motion artifacts (31) similar to those seen in PaO2 measurements cannot be avoided and are a confounding factor for both types of measurements. Intensive care nurses are properly trained on the working principles of pulse oximetry, and faulty use is rare (32). Motion tolerant SpO2 sensors are now commercially available, which will likely reduce this artifact in the near future.
The current results, which were obtained using an extremely large database, are consistent with others showing an excellent correlation and agreement between S/F and P/F ratios in non-burned critically ill pediatric patients (13–17). Only Perkins et al. found a low correlation (r = 0.60), which was derived from analysis of 41 critical ill adults and 1,085 concomitant measurements (33).
According to the PALICC, OI and OSI index can be used in addition to the P/F ratio and S/F ratio for the diagnosis of ARDS, as well as for grading ARDS severity. The OI and OSI index are extremely useful, especially in children because they incorporate the effects of mean airway pressure. Use of the OI and OSI index has been widely adopted and considering our results, should also be considered in burned children with SSI. Unfortunately, we were not able to analyze these two indices in our cohort because the mean airway pressure data were not available.
The major limitation of our study is its retrospective design, which can potentially influence the results, as no precise data were available on events such as displacement of the pulse oximetry occurred simultaneously during the matching ratio measurements. However, eliminating the matches with PaO2 greater than 100 mmHg (100 torr) and SpO2 lower than 92% limited this effect. A second limitation is that we were unable to obtain end-tidal CO2 measurements to investigate eventual minute ventilation management, since these values are not recorded at our institution. Additionally, the effect of acid-base disturbance on the oxyhemoglobin dissociation curve was not taken in consideration. Lastly, we were unable to quantify the possible interference of low perfusion rates and determine how these may have influenced the SpO2 readings.
In conclusion, our results support a strong correlation between the S/F and P/F ratio in burned children with SII. Moreover, our results, suggest that SpO2 values can be used as a surrogate for PaO2 values, especially in patients with low oxygen saturation and at risk for development of ARDS. Nonetheless, arterial blood samples remain an invaluable part of the critical care armamentarium. Future prospective studies investigating OI and OSI index in burn patients with SII are needed to validate and confirm our findings and to further improve the diagnosis of ARDS.
Acknowledgments
Support: This study was supported by the National Institutes of Health (P50GM060338, R01GM056687, T32GM8256, R01HD049471), Shriners Hospitals for Children (SHC 84080, SHC 80100, SHC 71008, SHC 71009, SHC 71006), and the United States Department of Defense (W81XWH-12-1-0598).
Drs. Cambiaso-Daniel, Voigt, Hundeshagen, Rivas, Sljivich, Herndon, and Suman received support for article research from the National Institutes of Health (NIH). Drs. Voigt, Hundeshagen, Rivas, and Sousse’s institutions received funding from the NIH (P50GM060338, R01GM056687, T32GM8256, R01HD049471) and from the Department of Defense (DoD) (W81XWH-12-1-0598). Dr. Nunez-Lopez received support for article research from the NIH (P50GM060338, R01GM056687, T32GM8256, R01HD049471) and the DoD (W81XWH-12-1-0598) Dr. Sousse received support for article research from the NIH and the DoD. Dr. Herndon’s institution received funding from the NIH, NIDILRR, the DoD, Shriners of North America, and Gillson-Longenbaugh Foundation. Dr. Suman’s institution received funding from the NIH, the DoD, and Shriners Hospitals for Children. Dr. Kinsky’s institution received funding from the NIH and the DoD, and he received support for article research from the NIH and the DoD.
Footnotes
Copyright form disclosure: The remaining authors have disclosed that they do not have any potential conflicts of interest.
References
- 1.Smolle C, Cambiaso-Daniel J, Forbes AA, Wurzer P, Hundeshagen G, Branski LK, et al. Recent trends in burn epidemiology worldwide: A systematic review. Burns : journal of the International Society for Burn Injuries. 2016 doi: 10.1016/j.burns.2016.08.013. Epub 2016/09/08. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Barrow RE, Przkora R, Hawkins HK, Barrow LN, Jeschke MG, Herndon DN. Mortality related to gender, age, sepsis, and ethnicity in severely burned children. Shock. 2005;23(6):485–7. Epub 2005/05/18. [PubMed] [Google Scholar]
- 3.Brusselaers N, Hoste EA, Monstrey S, Colpaert KE, De Waele JJ, Vandewoude KH, et al. Outcome and changes over time in survival following severe burns from 1985 to 2004. Intensive care medicine. 2005;31(12):1648–53. doi: 10.1007/s00134-005-2819-6. Epub 2005/10/13. [DOI] [PubMed] [Google Scholar]
- 4.Meshulam-Derazon S, Nachumovsky S, Ad-El D, Sulkes J, Hauben DJ. Prediction of morbidity and mortality on admission to a burn unit. Plastic and reconstructive surgery. 2006;118(1):116–20. doi: 10.1097/01.prs.0000221111.89812.ad. Epub 2006/07/04. [DOI] [PubMed] [Google Scholar]
- 5.Osler T, Glance LG, Hosmer DW. Simplified estimates of the probability of death after burn injuries: extending and updating the baux score. The Journal of trauma. 2010;68(3):690–7. doi: 10.1097/TA.0b013e3181c453b3. Epub 2009/12/30. [DOI] [PubMed] [Google Scholar]
- 6.Ware LB, Matthay MA. The acute respiratory distress syndrome. The New England journal of medicine. 2000;342(18):1334–49. doi: 10.1056/NEJM200005043421806. Epub 2000/05/04. [DOI] [PubMed] [Google Scholar]
- 7.Rubenfeld GD, Caldwell E, Peabody E, Weaver J, Martin DP, Neff M, et al. Incidence and outcomes of acute lung injury. The New England journal of medicine. 2005;353(16):1685–93. doi: 10.1056/NEJMoa050333. Epub 2005/10/21. [DOI] [PubMed] [Google Scholar]
- 8.Sine CR, Belenkiy SM, Buel AR, Waters JA, Lundy JB, Henderson JL, et al. Acute Respiratory Distress Syndrome in Burn Patients: A Comparison of the Berlin and American-European Definitions. Journal of burn care & research : official publication of the American Burn Association. 2016;37(5):e461–9. doi: 10.1097/BCR.0000000000000348. Epub 2016/04/14. [DOI] [PubMed] [Google Scholar]
- 9.Jeschke MG, Pinto R, Kraft R, Nathens AB, Finnerty CC, Gamelli RL, et al. Morbidity and survival probability in burn patients in modern burn care. Critical care medicine. 2015;43(4):808–15. doi: 10.1097/CCM.0000000000000790. Epub 2015/01/07. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Bernard GR, Artigas A, Brigham KL, Carlet J, Falke K, Hudson L, et al. The American-European Consensus Conference on ARDS. Definitions, mechanisms, relevant outcomes, and clinical trial coordination. American journal of respiratory and critical care medicine. 1994;149(3 Pt 1):818–24. doi: 10.1164/ajrccm.149.3.7509706. Epub 1994/03/01. [DOI] [PubMed] [Google Scholar]
- 11.Ranieri VM, Rubenfeld GD, Thompson BT, Ferguson ND, Caldwell E, Fan E, et al. Acute respiratory distress syndrome: the Berlin Definition. Jama. 2012;307(23):2526–33. doi: 10.1001/jama.2012.5669. Epub 2012/07/17. [DOI] [PubMed] [Google Scholar]
- 12.Khemani RG, Smith LS, Zimmerman JJ, Erickson S Pediatric Acute Lung Injury Consensus Conference G. Pediatric acute respiratory distress syndrome: definition, incidence, and epidemiology: proceedings from the Pediatric Acute Lung Injury Consensus Conference. Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies. 2015;16(5 Suppl 1):S23–40. doi: 10.1097/PCC.0000000000000432. Epub 2015/06/04. [DOI] [PubMed] [Google Scholar]
- 13.Rice TW, Wheeler AP, Bernard GR, Hayden DL, Schoenfeld DA, Ware LB. Comparison of the SpO2/FIO2 ratio and the PaO2/FIO2 ratio in patients with acute lung injury or ARDS. Chest. 2007;132(2):410–7. doi: 10.1378/chest.07-0617. Epub 2007/06/19. [DOI] [PubMed] [Google Scholar]
- 14.Khemani RG, Patel NR, Bart RD, 3rd, Newth CJ. Comparison of the pulse oximetric saturation/fraction of inspired oxygen ratio and the PaO2/fraction of inspired oxygen ratio in children. Chest. 2009;135(3):662–8. doi: 10.1378/chest.08-2239. Epub 2008/11/26. [DOI] [PubMed] [Google Scholar]
- 15.Lobete C, Medina A, Rey C, Mayordomo-Colunga J, Concha A, Menendez S. Correlation of oxygen saturation as measured by pulse oximetry/fraction of inspired oxygen ratio with Pao2/fraction of inspired oxygen ratio in a heterogeneous sample of critically ill children. Journal of critical care. 2013;28(4):538, e1–7. doi: 10.1016/j.jcrc.2012.12.006. Epub 2013/02/12. [DOI] [PubMed] [Google Scholar]
- 16.Thomas NJ, Shaffer ML, Willson DF, Shih MC, Curley MA. Defining acute lung disease in children with the oxygenation saturation index. Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies. 2010;11(1):12–7. doi: 10.1097/PCC.0b013e3181b0653d. Epub 2009/06/30. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Khemani RG, Thomas NJ, Venkatachalam V, Scimeme JP, Berutti T, Schneider JB, et al. Comparison of SpO2 to PaO2 based markers of lung disease severity for children with acute lung injury. Critical care medicine. 2012;40(4):1309–16. doi: 10.1097/CCM.0b013e31823bc61b. Epub 2011/12/29. [DOI] [PubMed] [Google Scholar]
- 18.Ralston AC, Webb RK, Runciman WB. Potential errors in pulse oximetry. I. Pulse oximeter evaluation. Anaesthesia. 1991;46(3):202–6. doi: 10.1111/j.1365-2044.1991.tb09410.x. Epub 1991/03/01. [DOI] [PubMed] [Google Scholar]
- 19.Flori HR, Glidden DV, Rutherford GW, Matthay MA. Pediatric acute lung injury: prospective evaluation of risk factors associated with mortality. American journal of respiratory and critical care medicine. 2005;171(9):995–1001. doi: 10.1164/rccm.200404-544OC. Epub 2004/12/25. [DOI] [PubMed] [Google Scholar]
- 20.King MA, Garrison MM, Vavilala MS, Zimmerman JJ, Rivara FP. Complications associated with arterial catheterization in children. Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies. 2008;9(4):367–71. doi: 10.1097/PCC.0b013e318172d94f. Epub 2008/05/23. [DOI] [PubMed] [Google Scholar]
- 21.Tsai YH, Lin MC, Hsieh MJ, Chen NH, Tsao TC, Lee CH, et al. Spontaneous variability of arterial oxygenation in critically ill mechanically ventilated patients. Intensive care medicine. 1999;25(1):37–43. doi: 10.1007/s001340050784. Epub 1999/03/02. [DOI] [PubMed] [Google Scholar]
- 22.Sasse SA, Chen PA, Mahutte CK. Variability of arterial blood gas values over time in stable medical ICU patients. Chest. 1994;106(1):187–93. doi: 10.1378/chest.106.1.187. Epub 1994/07/01. [DOI] [PubMed] [Google Scholar]
- 23.Merlani P, Garnerin P, Diby M, Ferring M, Ricou B. Quality improvement report: Linking guideline to regular feedback to increase appropriate requests for clinical tests: blood gas analysis in intensive care. BMJ. 2001;323(7313):620–4. doi: 10.1136/bmj.323.7313.620. Epub 2001/09/15. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Roberts D, Ostryzniuk P, Loewen E, Shanks A, Wasyluk T, Pronger L, et al. Control of blood gas measurements in intensive-care units. Lancet. 1991;337(8757):1580–2. doi: 10.1016/0140-6736(91)93271-a. Epub 1991/06/29. [DOI] [PubMed] [Google Scholar]
- 25.Jubran A. Pulse oximetry. Crit Care. 1999;3(2):R11–R7. doi: 10.1186/cc341. Epub 2000/11/30. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Barker SJ, Curry J, Redford D, Morgan S. Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study. Anesthesiology. 2006;105(5):892–7. doi: 10.1097/00000542-200611000-00008. Epub 2006/10/27. [DOI] [PubMed] [Google Scholar]
- 27.Buckley RG, Aks SE, Eshom JL, Rydman R, Schaider J, Shayne P. The pulse oximetry gap in carbon monoxide intoxication. Annals of emergency medicine. 1994;24(2):252–5. doi: 10.1016/s0196-0644(94)70137-7. Epub 1994/08/01. [DOI] [PubMed] [Google Scholar]
- 28.Comber JT, Lopez BL. Evaluation of pulse oximetry in sickle cell anemia patients presenting to the emergency department in acute vasoocclusive crisis. The American journal of emergency medicine. 1996;14(1):16–8. doi: 10.1016/S0735-6757(96)90005-4. Epub 1996/01/01. [DOI] [PubMed] [Google Scholar]
- 29.Saito S, Fukura H, Shimada H, Fujita T. Prolonged interference of blue dye "patent blue" with pulse oximetry readings. Acta anaesthesiologica Scandinavica. 1995;39(2):268–9. doi: 10.1111/j.1399-6576.1995.tb04055.x. Epub 1995/02/01. [DOI] [PubMed] [Google Scholar]
- 30.Ries AL, Prewitt LM, Johnson JJ. Skin color and ear oximetry. Chest. 1989;96(2):287–90. doi: 10.1378/chest.96.2.287. Epub 1989/08/01. [DOI] [PubMed] [Google Scholar]
- 31.Petterson MT, Begnoche VL, Graybeal JM. The effect of motion on pulse oximetry and its clinical significance. Anesthesia and analgesia. 2007;105(6 Suppl):S78–84. doi: 10.1213/01.ane.0000278134.47777.a5. Epub 2007/12/06. [DOI] [PubMed] [Google Scholar]
- 32.Giuliano KK, Liu LM. Knowledge of pulse oximetry among critical care nurses. Dimensions of critical care nursing : DCCN. 2006;25(1):44–9. doi: 10.1097/00003465-200601000-00013. Epub 2006/02/28. [DOI] [PubMed] [Google Scholar]