In situ labeling and vascular imaging |
Magnetic resonance imaging |
Gadolinium immobilized liposomes (75.9nm) |
Increased contrast and larger field of view for imaging small blood vessels |
Howles et al. [47] |
Photoacoustic imaging |
Hollow gold nanospheres (40 nm) |
Enhanced vascular contrast and visualization of vessels as small as ~100nm in diameter |
Lu et al. [48] |
Intravital imaging |
RGD-QDs (6–8 nm) |
QDs specifically targeted newly formed vessels expressing αvβ3 integrins |
Smith et al. [50] |
Magnetic resonance imaging |
Perfluorocarbon NPs (<300 nm) |
NPs targeted αvβ3 integrins and enhanced angiogenesis for L-arginine treated animals |
Winter et al. [49] |
Cell pre-labeling and imaging |
Fluorescent microscopy |
QDs |
QDs detectable up to 2 days or 14 days in vivo
|
Lin et al. [2] |
|
CdSe/ZnS QDs (10–15 nm) |
Dose-dependent cytotoxicity effects on MSCs |
Muller-Borer et al. [53] |
Photoacoustic imaging |
Gold NPs (20–60 nm) |
Gold NPs of various sizes and surface coatings did not compromise MSC function |
Ricles et al. [3] |
|
Gold NPs (20 nm) |
In vivo imaging of MSCs up to day 10 |
Nam et al. [4] |
Multi-photon photoluminescence imaging |
Gold NPs (10 nm) |
ESC function not compromised and cells were imaged in vitro
|
Nagesha et al. [63] |
Magnetic resonance imaging |
SPIO |
NP labeling had no effect on cell function, and the cells could be tracked in vivo up to 18 weeks |
Guzman et al. [66] |
|
Carboxy-dextran-coated iron oxide NPs |
MSCs were in the renal cortex up to three days and renal function was significantly improved |
Lange et al. [5] |
|
Poly-L-lysine coated magnetic NPs |
MSCs were visible in MI model up to 1 week, but there was significant decrease in signal after 3 weeks |
Kraitchman et al. [67] |
Magnetic resonance and fluorescence imaging |
SPIO@SiO2(FITC) |
In vivo imaging of MSCs labeled with FITC-incorporated silica-coated core-shell SPIO NPs |
Lu et al. [68] |
Magnetic resonance imaging and X-ray |
Fe3O4/gold nanohybrids (35 nm) |
Nanohybrids did not alter cell function and could be imaged with MRI and CT with enhanced contrast |
Narayanan et al. [69] |
Positron emission tomography and magnetic resonance imaging |
SPIO@SiO2
|
High uptake efficiency of SPIO core NPs in MSCs and no cytotoxic effects |
Patel et al. [70] |