Skip to main content
. 2017 Oct 4;8:1877. doi: 10.3389/fmicb.2017.01877

Table 3.

Detection limits of LAMP and PCR assays detecting DNAs of non-Hib serotypes and using the DNA spiked CSF specimens.

Non-Hib serotypes Detection limit (Purified DNA)
Detection limit (Spiked CSF)
PCRa,b LAMPa PCRa,b LAMPa
a 104 copiesc 102 104 copiesc 102
c 104 102 104 102
d 103 102 104 102
e 103 103 105 103
f 104 10 104 10

aPCR results were obtained by electrophoretic analysis. LAMP results were determined visually. bConventional PCR (Falla et al., 1994). cAmount of DNA per reaction.