Table 1.

Assessment of agreement between Fitbit and EKG (N=22). Mean Difference is computed by subtracting EKG-derived heart rate from the Fitbit-measured heart rate, and reported in beats per minute

Comparison ICC (95% CI) Mean Difference (95% Limits of Agreement)
Single measures 0.83 (0.67, 0.90) −6.04 (−26.42, 14.35)
5 sec moving average 0.83 (0.66, 0.90) −6.07 (−25.73, 13.59)
10 sec moving average 0.84 (0.65, 0.91) −6.07 (−25.08, 12.95)