Skip to main content
. 2017 Oct 10;13:81. doi: 10.1186/s13007-017-0235-x

Table 1.

Comparison of the main steps of the process by conventional and improved methods

Step Conventional method Improved method Δ* (%)
Required sample (mg) 1000 50 95
Extraction time
 Free phenolics (min) 15 30 − 100
 Bound phenolics (h) 12 10 17
Drying time (days) 7 2 71
Consumed solvents
 Free phenolics (mL) 90 46 49
 Bound phenolics (mL) 1080 376 65
Solvents waste (mL) 324 106 67
Number of samples per batcha 9 66 − 633

Δ*: Difference between conventional and improved methods expressed as percentages

aAccording to the capabilities of the available centrifuge equipment