Table 4.

Effect of cell dose used for BMC transplantation left ventricular function

No. of RCTs Difference in mean (95% CI) P value
LV ejection fraction
 Cell dose ≤ 10^7 3 1.91 [–0.05 to 3.87] 0.06
 Cell dose > 10^7, ≤ 10^8 11 1.56 [–2.95 to 6.06] 0.50
 Cell dose > 10^8, ≤ 10^9 16 1.65 [0.22 to 3.09] 0.02
 Cell dose > 10^9, ≤ 10^10 4 5.87 [0.79 to 10.95] 0.02
LV end-diastolic indexes
 Cell dose ≤ 10^7 3 –6.00 [–15.20 to 3.20] 0.20
 Cell dose > 10^7, ≤ 10^8 8 –7.36 [–11.45 to –3.27] 0.0004
 Cell dose > 10^8, ≤ 10^9 12 –0.69 [–2.22 to 0.83] 0.37
 Cell dose > 10^9, ≤ 10^10 3 4.63 [–1.74 to 11.00] 0.15
LV end-systolic indexes
 Cell dose ≤ 10^7 3 –8.01 [–17.88 to 1.87] 0.11
 Cell dose > 10^7, ≤ 10^8 6 –12.99 [–19.07 to –6.91] < 0.0001
 Cell dose > 10^8, ≤ 10^9 11 0.32 [–1.62 to 2.26] 0.75
 Cell dose > 10^9, ≤ 10^10 3 –1.50 [–6.90 to 3.89] 0.59

RCTs randomized controlled trials, 95% CI 95% confidence interval