Table 4.

Computed tomography values (HU), standard deviation of computed tomography values (SD) and signal-to-noise ratio obtained with standard-dose and low-dose protocols

Low-dose Standard-dose P-value
HUaorta (n = 51) 166.20 ± 18.83 154.17 ± 24.82 < 0.001
HUliver (n = 51) 112.55 ± 16.49 103.90 ± 17.49 < 0.001
HUspleen (n = 51) 126.24 ± 13.60 112.77 ± 15.66 < 0.001
SDliver (n = 51) 16.81 ± 2.02 14.41 ± 3.33 < 0.001
SDspleen (n = 51) 16.78 ± 2.04 14.72 ± 3.26 < 0.001
SDfat (n = 51) 12.17 ± 2.77 12.07 ± 2.98 0.307
SNRliver (n = 51) 6.94 ± 1.32 7.80 ± 2.30 0.002
SNRliver Group A (n = 8) 8.09 ± 1.63 9.36 ± 2.27 0.05
SNRliver Group B (n = 25) 6.95 ± 1.22 8.53 ± 1.97 < 0.001
SNRliver Group C (n = 13) 6.47 ± 1.00 6.66 ± 1.34 0.972
SNRliver Group D (n = 5) 6.29 ± 1.19 4.60 ± 1.77 0.08
SNRspleen (n = 51) 7.73 ± 1.46 8.10 ± 2.04 0.153
SNRspleen Group A (n = 8) 9.25 ± 2.31 10.53 ± 1.69 0.092
SNRspleen Group B (n = 25) 7.60 ± 1.10 8.04 ± 1.86 0.177
SNRspleen Group C (n = 13) 7.26 ± 1.11 7.20 ± 1.45 0.65
SNRspleen Group D (n = 5) 7.21 ± 0.82 6.86 ± 1.89 0.893

SNR: Signal-to-noise ratio.