Table 3.

Univariate Analysis of Factors Predicting Pneumothorax after Microwave Ablation

Odds Ratio Confidence Interval P Value
Ablation power (W) 1.0 0.97–1.04 .94
Temperature (°C) 1.0 0.95–1.03 .66
Probe geometry (perpendicular vs parallel) 2.8 0.78–9.71 .11
Probe angle (°) 1.0 1.00–1.04 .11
Emitting point to pleural puncture distance (cm) 0.6 0.35–1.16 .14
Emitting point to closest pleura distance (cm) 0.5 0.12–2.38 .42
Ablation zone includes pleural puncture site (yes vs no) 4.1 1.00–16.7 .05
Ablation zone long axis (cm) 0.6 0.23–1.64 .33
Ablation zone short axis (cm) 0.4 0.10–1.65 .21
Ablation zone area (cm2) 0.8 0.55–1.12 .18
Pleural contact with ablation zone (cm) 0.9 0.54–1.55 .74
No. ablations in each lung 1.5 1.03–2.28 .04
Time since intubation (h) 2.8 1.33–5.84 .01