Skip to main content
. 2017 Oct 24;61(11):e01201-17. doi: 10.1128/AAC.01201-17

TABLE 3.

Geometric mean TT anticoagulation parameters in arm A (RTV)a

Parameter AUEC0–24 (s · h) TT24 (s)
Geometric mean value (% CV)
    Phase 1 (DE alone) 1,479 (20.7) 28.6 (27.3)
    Phase 2 (DE + RTV separated) 1,320 (18.7) 25.3 (17.8)
    Phase 3 (DE + RTV simultaneously) 1,424 (26.6) 37.4 (27.6)
GMR (90% CI) for comparison of phases
    Phase 2 vs phase 1 0.89 (0.79–1.00) 0.88 (0.76–1.01)
    Phase 3 vs phase 1 0.96 (0.82–1.11) 1.31 (1.09–1.52)b
a

AUEC0–24, area-under-the-time-effect curve from time zero to 24 h; DE, dabigatran etexilate; RTV, ritonavir; TT24, thrombin time at 24 h; CV, coefficient of variation; CI, confidence interval.

b

P < 0.05, based on a paired Student t test.