Skip to main content
. 2017 Oct 25;7:14003. doi: 10.1038/s41598-017-14117-1

Figure 1.

Figure 1

(a) Surface barrier discharge electrode configuration, showing the experimental configuration with the computational model domain superimposed, all key dimensions in the model were chosen to match the experimental setup. For the computational model, the highlighted plasma domain is the region where the equations describing the plasma are solved and the transport domain is where the flow equations are solved, and (b) phase shifted sinusoidal voltage waveforms applied to the right-hand electrode. The model was solved for d = 5 mm case only.