Table 3.
Publication | Type of images | Proposed methods | Comparison baseline | ||
---|---|---|---|---|---|
Method | Results | Method | Results | ||
Liu et al. [52] | MRI | CNN + RF | ACC = 0.9545 | CHF | ACC = 0.9091 |
Paul et al. [54] | Contrast-enhanced CT | CNN + SUFRA + RF | AUC = 0.935 | TQF + DT | AUC = 0.712 |
Notes. MRI = magnetic resonance imaging; CNN = convolutional neural network; RF = random forest; ACC = accuracy; CHF = conventional histogram feature; CT = computer tomography; SUFRA = symmetric uncertainty feature ranking algorithm [60]; AUC = area under the receiver operating characteristic curve; TQF = traditional quantitative features; DT = decision tree.