Definition of condition grades (CCs) used in the building inspection reports.

CC0 No remarks (faultless). Documentation of professional execution/correct construction, including material use and technical solutions is presented when necessary.
CC1 As CC0, but the building part/construction has minor wear without need of measures.
CC2 The building part is not constructed correctly, is damaged (or has symptoms of damage), is considerably worn, or with reduced function. Measures are needed or there is short remaining life expectancy. May also include lack of documentation of correct construction of structures or building parts at particular risk of moisture damage.
CC3 Total malfunction. The building part/construction does no longer fulfill its purpose, or deviates from building regulations/rules. Need for urgent measures.