Contraction stress before and after 56 days water immersion, contraction stress drop, absorbency, and solubility of tested materials.

Material Contraction Stress after 0.5 h (MPa) Contraction Stress after 56 Days of Water Immersion (MPa) Contraction Stress Drop (%) Sorption (µg/mm3) Solubility (µg/mm3)
Filtek Ultimate 10.2 ± 1.1 2.3 ± 1.1 77 27.1 ± 1.1 2,8 ± 1,5
Gradia Direct LoFlo 12.0 ± 0.9 3.1 ± 0.1 74 35.0 ± 0.9 2.1 ± 0.5
Heliomolar Flow 9.9 ± 0.9 2.6 ± 0.9 74 34.6 ± 0.3 2.6 ± 0.4
Tetric EvoCeram 7.0 ± 1.1 0.8 ± 0.2 89 19.5 ± 1.1 1.1 ± 0.1
Tetric EvoCeram Bulk Fill 6.3 ± 0.3 3.1 ± 0.1 51 17.7 ± 1.0 1.1 ± 0.8
Tetric EvoFlow 9.4 ± 0.5 4.7 ± 0.2 50 20.2 ± 0.3 2.4 ± 0.2
Tetric EvoFlow Bulk Fill 9.4 ± 0.3 4.7 ± 0.2 50 10.6 ± 0.1 1.7 ± 0.3
X-tra Base 10.4 ± 0.9 4.7 ± 0.2 55 6.6 ± 2.3 0.2 ± 0.1
Venus BulkFil 8.1 ± 1.1 4.2 ± 0.9 48 17.4 ± 0.6 2.0 ± 0.6
Ceram.X one 12.5 ± 0.4 6.3 ± 0.2 50 15.9 ± 1.2 0.5 ± 0.1