Skip to main content
. 2017 Oct 30;13(5):550–558. doi: 10.12965/jer.1735104.552

Table 2.

Mean±standard deviation anterior displacement (mm) for the injured and the noninjured knees at the three different time-points of Rolimeter readings (n=15)

Time-points Injured knee Noninjured knee Side-to-side difference Two-way ANOVA F statistic P-value ES
Baseline 9.3±2.3 6.7±1.8 2.6±2.5 Condition effect* F (1,14)=16.9 0.001 0.55
Midpoint 9.7±2.2 6.9±1.8 2.8±2.4 Time-point effect F (2,28)=1.7 0.208 0.11
Endpoint 9.5±2.7 6.9±1.8 2.7±2.9 Interaction effect F (2,28)=0.3 0.775 0.02

Side-to-side difference, defined as the difference between the injured and the noninjured knee. F, P-value, and effect size (ES) were obtained by a two-way analysis of variance (ANOVA) (2×3: knee conditions vs. time-points).

Significant two-way ANOVA effect for condition* (i.e., injured versus noninjured knee).