Table 6. Comparison of radiation doses between patients with low and high radiation toxicity.

Radiation mucositis Radiation dermatitis
Oral cavity Larynx Skin1 Skin4mm2
G0-2 G3+ G0-2 G3+ G0-1 G2+ G0-1 G2+
n 91 83 91 83 86 31 68 20
Radiation dose (mean±SD, cGy) 3893.65±545.20 3930.05±551.43 4215.65±350.68 4215.06±325.32 3496.06±722.31 3245.97±583.61 3656.47±462.32 3577.97±475.70
P 0.662 0.991 0.086 0.509

1 The mean dose of skin was calculated in only 117 patients when the radiotherapy plan was performed.

2 The mean dose of skin4mm was calculated in only 88 patients when the radiotherapy plan was performed.

SD, standard deviation.