Skip to main content
. 2017 Nov 2;7:14888. doi: 10.1038/s41598-017-13993-x

Table 1.

Parameters used in modeling the tonic and Ag-triggered survival signals.

Parameter Initial value range Optimum value ± SD (%)a Unit
d 1 0.01435 /h
k 1 0–0.2 0.02980 ± 0.4695% /h
k 2 2.779 ml/μg/h
k 3 3.145 /h
k 4 0–0.2 0.1294 ± 1.795% /h
d 2 0–0.2 0.1543 ± 0.3359% /h
offset 0–1.0 0.6097 ± 0.8074%
deadline 0–0.2 0.01032 ± 0.7700%

aParameters without initial value range were calculated based on experimental data and those with initial value range were optimized using genetic algorithm. The variations in the optimal value in the 10 seeds of random numbers are shown.