Skip to main content
. Author manuscript; available in PMC: 2017 Nov 3.
Published in final edited form as: J Comput Phys. 2016 Jul 11;323:219–242. doi: 10.1016/j.jcp.2016.06.038

Table 2.

Parameters used in the idealized artery model simulations.

Parameter Value
Young’s Modulus 0.3 Mpa
Poisson ratio 0.3
Blood density 1.06 g/cm3
Wall thickness 0.0105 cm
Inlet radius 0.1 cm
Kinematic viscosity 3.8×10−2 cm2/s
Average flow rate 20 ml/min
Time step size 9.4×10−5 s
Polynomial order 3
Fictitious mass coefficient 2.16