Skip to main content
. 2017 Nov 6;10:549. doi: 10.1186/s13071-017-2498-5

Table 2.

Configuration of the two types of microclimatic stations used at the 25 study sites

No. of sensors Parameters measured Height of sensor Sensor specification
Basic measurement sites (20 sites)a
 1 Ta, RH 50 cm above soil surface S-THB-M002, Onset
 1 Ts 5 cm under soil surface S-TMB-M002, Onset
 1 soil moisture 5 cm under soil surface S-SMC-M005, Onset
Intensive measurement site (5 sites)b
 2 Ta, RH 50 cm above soil surface HygroClip 2, Rotronic
 1 Tlitter, RH 0.5 cm (on soil surface) HygroClip 2, Rotronic
 4 Ts (at 4 spots) 5 cm under soil surface SKTS 200, Skye
 1 soil moisture 5 cm under soil surface Hydra Probe II, Stevens
 1 Ta, RH 2 m (inside the forest) HygroClip 2, Rotronic
 1 Ta, RH, SR, W, prec, BP 2 m (outside the forest) Weather Transmitter WXT520, Vaisala

aLogger: HOBO Micro Station Data Logger H21–002, Onset Computer Corporation

bLogger: SDI-Log40 Data Logger, UP GmbH

Abbreviations: BP barometric pressure, prec precipitation, Ta air temperature, Ts soil temperature, RH relative humidity, SR solar radiation, W wind speed/direction