Specifications of the stationary Monitoring Sensor Units (MSUs) for gaseous pollutant measurement.

Pollutant CO NO NO2 O3 NO2 O3 Total VOC (TVOC) (CO2-Equivalent)
Sensor technology Electrochemical
(EC)
Electrochemical
(EC)
Electrochemical
(EC)
Electrochemical
(EC)
Metal oxide (MO) Metal oxide (MO) Metal oxide (MO)
Sensor provider Alphasense Alphasense Alphasense Alphasense Applied Sensors Aeroqual Applied Sensors
Sensor type CO-B4 NO-B4 NO2-B42F OX-B421 iAQ-100 SM50 iAQ-100
Platform manufacturer Environmental Instruments (UK) Environmental Instruments (UK) Environmental Instruments (UK) Environmental Instruments (UK) Perkin Elmer (USA) Perkin Elmer (USA) Perkin Elmer (USA)
MSU type AQMesh AQMesh AQMesh AQMesh Elm Elm Elm
Measurement range
Sampling frequency
0–5000 ppb
1 min
0–2000 ppb
1 min
0–200 ppb
1 min
0–200 ppb
1 min
10–2000 ppb
20 s
0–150 ppb
1 min
0–2000 ppm