Table 1.

Imaging pulse sequences and parameters. For in-vivo acquisition, a flow compensated 3D GRE sequence was used to generate data for QSM and a Multi-Echo 3D GRE sequence for T2* mapping data. A Multi-Echo 3D GRE acquisition was used to collect ex-vivo QSM and T2* mapping data. Abbreviations: NE: Number of echoes, NSA: Number of signal averages.

Parameter ∖ Pulse seq. In-vivo (QSM): Flow compensated 3D GRE In-vivo (T2*): 3D multi-echo GRE Ex-vivo (QSM/T2*): 3D multi-echo GRE
TR (ms) 250 250 200
minTE/ΔTE/maxTE (ms) 15 2.31/2.46/29.32 3.05/3.92/46.21
FA (0) 32 32 36
NE 1 12 12
NSA 1 1 5
Scan time 1hr,2s 1hr,2s 10hr,45min,2s
Spectral width (Hz) 50000 100000 73529
FOV (mm) 18 × 18 × 18 18 × 18 × 18 18 × 17.2 × 14.4
Matrix 120 × 120 × 120 120 × 120 × 120 225 × 215 × 180
Resolution (μm) 150 × 150 × 150 150 × 150 × 150 80 × 80 × 80