Skip to main content
. 2017 Nov 7;359:j4788. doi: 10.1136/bmj.j4788

Table 2.

Diagnosis of type 1 myocardial infarction using high sensitivity cardiac troponin

Type 1 myocardial infarction Total Diagnostic parameter, % (95% CI)
Yes No Sensitivity Specificity Negative predictive value Positive predictive value
Unselected cohort (n=1054)
High sensitivity cardiac troponin >99th centile: - - - 100 (80.5 to 100) 87.7 (85.6 to 90.0) 100 (99.6 to 100) 11.8 (7.0 to 18.2)
 Yes 17 127 144
 No 0 910 910
Total 17 1037 1054
Selected cohort, UK (n=5815)
High sensitivity cardiac troponin >99th centile: - - - 100 (99.6 to 100) 88.5 (87.6 to 89.4) 100 (99.9 to 100) 59.7 (57.0 to 62.2)
 Yes 843 570 1413
 No 0 4402 4402
Total 843 4972 5815
Selected cohort, US (n=1631)
High sensitivity cardiac troponin >99th centile: - - - 100 (94.7 to 100) 77.8 (75.7 to 79.8) 100 (99.7 to 100) 16.4 (13.0 to 20.3)
 Yes 68 347 415
 No 0 1216 1216
Total 68 1563 1631