Published in final edited form as: Electrochim Acta. 2016 Aug 31;216:171–180. doi: 10.1016/j.electacta.2016.08.108

Table 1.

Comparisons of electroanalytical methods based on CV and potential step methods.

Potential windows (V) Epeak (V) Calibration curves based on CV curves i (nA)∝CCH3CHO (ppm) Amperometric sensor methods Eapplied (V) Calibration curves based on potential steps i (nA)∝CCH3CHO (ppm)
0 ~ + 1.2 +0.9 (Ox1‴) i = 6.54*C + 2.26E4 Single-potential step +0.9 i = 1.42*C + 7.06E2
−0.7 ~ + 1.2 +0.9 (Ox1″) i = 34.6*C + 4.88E4 Double-potential step +0.9 i = 2.68*C + 1.35E4
−0.5 (Red1) i = −42.1*C − 2.15E4 −0.5 i = −3.21*C − 4.86E3
−1.5 ~ + 1.2 −1.2 (Red2) i = −16.8*C − 3.49E5 Triple-potential step −1.2 i = −1.95*C − 1.45E5
+0.5 (Ox1) i = 20.6*C + 1.23E5 +0.5 i = 1.86*C + 1.81E4
−0.5 (Red1) i = −37.8*C − 9.73E3 −0.5 i = −4.18*C − 1.26E4