Skip to main content
. 2017 Nov 9;17:415–425. doi: 10.1016/j.nicl.2017.10.036

Table 2.

Multiple regression parameters for significant predictors of aural preference.

Cortex Predictor Bivariate
Partial
R2 P-value R2 P-value Adjusted P-value
Ipsilateral to HA Component: Pre-CI hearing experience 0.15 0.03 0.13 0.04 0.08
Duration of hearing aid use before implantation 0.24 < 0.01 0.26 < 0.01 0.02
Ipsilateral to CI Component: Post-CI hearing experience 0.14 0.04 0.17 0.02 0.06
Duration of implant use 0.10 0.07 0.12 0.05 0.08