Skip to main content
. 2016 Jul 19;7(1):27–33. doi: 10.1016/j.jpha.2016.07.005

Table 1.

Literature review on the electrochemical study of doxorubicin.

Electrode Modifier Method Linear range (μ M) LODa (μM) Application Ref.
GCEb MWCNTs/AgNPsc CV, DPV 0.0008–0.019 0.002 [25]
GCE PSd/Fe3O4-GO-SO3H DPV 0.043–3.5 0.0049 Plasma [26]
CPEe Carbon paste DPV 0.1–10 0.01 Urine [27]
CPE No modifier CV, DPV 0.01–100 [28]
GCE DNA sensorf DPV, Impedimetric 0.001–100 0.0001 Drugs, artificial plasma [29]
HMDEg No modifier SWVh 0.5–10 0.1 [30]
GCE GODi CV, DPV 0.02–3.6 0.016 Plasma [31]
Pt MWCNTs CV 0.09–7.36 0.003 Plasma This work
a

Limit of detection.

b

Glassy carbon electrode.

c

Silver nanoparticles/Multi-walled carbon nanotubes.

d

Polystyrene.

e

Carbon paste electrode.

f

Electropolymerized Neutral Red/polycarboxylated thiacax[4]aren/DNA.

g

Hanging mercury drop electrode.

h

Square wave voltammetry.

i

Graphene quantum dots.