TABLE 3.
Masked thresholds for the seven subjects of experiment 3 in backward and forward masking. Masked thresholds, as well as detection thresholds in quiet, are also shown for the four subjects who took part in the control forward masking experiment with a long masker-signal gap. Data for a given value of C (−1 or 0) are shown in plain type, with the threshold difference shown in bold type. The means and 95 % confidence intervals are shown in italics for the main experiment in the bottom two rows
Backward | Forward | Fwd, long gap | Quiet | |||||||
---|---|---|---|---|---|---|---|---|---|---|
−1 | 0 | Diff | −1 | 0 | Diff | −1 | 0 | Diff | ||
S1 | 44.5 | 35.0 | 9.5 | 63.5 | 49.2 | 14.3 | 29.0 | 28.3 | 0.7 | 24.3 |
S2 | 57.9 | 46.4 | 11.4 | 57.9 | 50.0 | 8.0 | ||||
S3 | 38.9 | 37.3 | 1.6 | 56.2 | 47.6 | 8.6 | 30.8 | 32.4 | −1.6 | 28.0 |
S4 | 47.4 | 54.7 | −7.3 | 44.1 | 44.6 | −0.5 | 35.6 | 36.7 | −1.1 | 34.3 |
S5 | 72.3 | 47.8 | 24.4 | 69.7 | 50.5 | 19.3 | 37.0 | 36.7 | 0.3 | 35.6 |
S6 | 46.8 | 42.6 | 4.2 | 47.4 | 39.0 | 8.4 | ||||
S7 | 37.6 | 38.1 | −0.5 | 52.9 | 47.5 | 5.3 | ||||
Mean | 49.3 | 43.1 | 6.2 | 56.0 | 46.9 | 9.1 | ||||
95 % CI | 9.0 | 5.2 | 7.5 | 6.6 | 3.0 | 4.7 |