Skip to main content
. 2017 Aug 23;18(6):815–825. doi: 10.1007/s10162-017-0637-5

TABLE 3.

Masked thresholds for the seven subjects of experiment 3 in backward and forward masking. Masked thresholds, as well as detection thresholds in quiet, are also shown for the four subjects who took part in the control forward masking experiment with a long masker-signal gap. Data for a given value of C (−1 or 0) are shown in plain type, with the threshold difference shown in bold type. The means and 95 % confidence intervals are shown in italics for the main experiment in the bottom two rows

Backward Forward Fwd, long gap Quiet
−1 0 Diff −1 0 Diff −1 0 Diff
S1 44.5 35.0 9.5 63.5 49.2 14.3 29.0 28.3 0.7 24.3
S2 57.9 46.4 11.4 57.9 50.0 8.0
S3 38.9 37.3 1.6 56.2 47.6 8.6 30.8 32.4 −1.6 28.0
S4 47.4 54.7 −7.3 44.1 44.6 −0.5 35.6 36.7 −1.1 34.3
S5 72.3 47.8 24.4 69.7 50.5 19.3 37.0 36.7 0.3 35.6
S6 46.8 42.6 4.2 47.4 39.0 8.4
S7 37.6 38.1 −0.5 52.9 47.5 5.3
Mean 49.3 43.1 6.2 56.0 46.9 9.1
95 % CI 9.0 5.2 7.5 6.6 3.0 4.7