Skip to main content
Journal of General and Family Medicine logoLink to Journal of General and Family Medicine
. 2017 Apr 13;18(3):139–143. doi: 10.1002/jgf2.16

Can we truly rely on the urinary antigen test for the diagnosis? Legionella case report

Jun Miyata 1,, Ji Young Huh 2, Yukiko Ito 1, Taketsune Kobuchi 1, Kazuko Kusukawa 1, Hiroyuki Hayashi 1
PMCID: PMC5689406  PMID: 29264010

Abstract

It is critical to diagnose and treat Legionella pneumonia (LP) immediately after infection because of the associated high mortality. The urine antigen test (UAT) is often used for the diagnosis of LP; however, it cannot detect the serogroups of all Legionella species. A detained medical history and several clinical findings such as liver enzyme elevation and hyponatremia are useful in diagnosis. Some specific types of Legionella are found in compost. Herein, we report a case of LP in which the patient's medical history and several clinical findings were useful for diagnosis.

Keywords: compost, gardening, Legionella longbeachae, Legionella pneumonia, loop‐mediated isothermal amplification, urine antigen test

1. Introduction

The urine antigen test (UAT) is often used in the primary care setting for the diagnosis of Legionella pneumonia (LP); however, the test is not adequately sensitive and the results are frequently uncertain. For the present case, the patient's medical history and several clinical findings proved essential for LP diagnosis. The UAT results could not aid the diagnosis owing to its limited sensitivity.

2. Case Presentation

A 69‐year‐old Japanese man presented to the emergency department for a 3 day history of a fever and chills. He did not have a cough, rhinorrhea, pharyngalgia, dyspnea, nausea, diarrhea, or loss of appetite. He had diabetes mellitus (HbA1c 7.0% 11 days before admission) and atrial fibrillation, and he was receiving glimepiride, sitagliptin, and warfarin medication. In terms of risk factors for LP, he was an ex‐smoker and a gardener, but had not traveled abroad or taken a public bath.

On physical examination, his body temperature was 36.3°C, his heart rate was 91 beats per minute, his blood pressure was 99/68 mm Hg, his respiratory rate was 16 breaths per minute, and his SpO2 was 98% in room air. Coarse crackles were heard in his right lower lung field. The rest of the physical examination was normal.

His laboratory test results are shown in Table 1. The blood test showed anemia, thrombocytopenia, liver enzyme elevation, hyponatremia, and elevated creatinine phosphokinase. Proteinuria and microhematuria were revealed via urine analysis. The result of a Legionella UAT was negative. We assessed his sputum Gram stain and classified it as Geckler group 6; no bacteria were detected in the smear. The sputum culture test showed the presence of only alpha‐hemolytic Streptococcus and Candida. It was negative for Legionella though we did not use the buffered charcoal yeast extract agar base to detect Legionella species. A chest radiograph and a computerized axial tomography scan showed consolidation in the right lower lobe (Figures 1 and 2).

Table 1.

Laboratory data on admission

Complete blood count Blood Chemistry Serology Arterial blood gas (Room air)
White blood cell 7700/μL T‐protein 6.3 g/dLa pH 7.433 mm Hg
Red blood cell 356×104/μLa T‐bil 0.7 mg/dL PaCO2 36.0 mm Hg
Hemoglobin 11.2 g/dLa AST 265 U/La PaO2 72.5 mm Hga
Hematocrit 31.5%a ALT 61 U/La HCO3 23.7 mmol/L
Platelet count 11.9×104/μLa LDH 572 U/La BE 0.2 mmol/L
ALP 196 U/L O2Sat 97.3%
Blood coagulation system CPK 15510 U/La AG 12.6 mmol/L
PT 17.7 sa Amy 47 U/L Lac 9 mg/dL
%PT 42.0%a BUN 28 mg/dLa
PT‐INR 1.54a Cr 1.65 mg/dLa
APTT 53.9 sa Na 126 mEq/La
K 3.5 mEq/L
Cl 92 mEq/La
Blood sugar 382 mg/dLa
CRP 19.79 mg/dLa
Urinalysis Urinary antigen test
Specific gravity 1.020 Ketone body Pneumococcus
pH 6.0 Blood 3+a Legionella
Protein 2+a Leukocyte
Glucose 2+a
a

Results out of the reference range.

Figure 1.

Figure 1

Chest radiography findings. The radiograph shows consolidation in the right lower lobe, which gradually disappeared after day 2

Figure 2.

Figure 2

Computed tomography findings. The image shows the consolidation spanning the entire right lower lobe region

Despite the negative UAT result, we initiated ceftriaxone, azithromycin, and minocycline treatment for LP because of a high clinical suspicion based on the clinical history and physical and laboratory findings. We confirmed the diagnosis using a sputum loop‐mediated isothermal amplification (LAMP) test (Eiken Chemical Co. Ltd, Japan). We administered levofloxacin because his body temperature was elevated (without relative bradycardia) and his bloody sputum persisted. Following treatment, he recovered and he was discharged on day 12 (Figure 3).

Figure 3.

Figure 3

Clinical course of the patient

3. Discussion

LP comprises 2% to 9% cases of community‐acquired pneumonia.1, 2, 3, 4, 5 Generally, legionellosis is caused by infections acquired from a water reservoir or hot spring contamination. The common risk factors of LP are cigarette smoking, chronic lung disease, increasing age, and immunosuppression. This patient had history of smoking and diabetes mellitus, which we considered risk factors of LP.

Generally, in cases of LP, respiratory symptoms such as cough and sputum are not prominent at first. Hyponatremia occurs frequently in legionellosis.1, 6, 7, 8, 9, 10 Renal and hepatic dysfunction, elevated creatinine phosphokinase, thrombocytopenia, and leukocytosis are considered the common laboratory abnormalities. Hematuria and proteinuria are also common abnormalities. In this case, the patient only complained of a fever and chills, and he did not have a cough or sputum. However, he eventually presented all the aforementioned laboratory features. A Gram stain of his sputum resulted in its classification as Geckler group 6, which did not aid the diagnosis.

While the mortality rate among patients with community‐acquired legionellosis ranges from 16% to 30%, with or without treatment using inactive antibiotics such as beta‐lactam agents, it reduces to less than 10% in patients with community‐acquired LP treated with potent therapies.11, 12, 13, 14, 15 In many countries, such as Japan, USA, and UK, cases of legionellosis should be reported immediately to the public health department. This is because earlier detection and appropriate diagnosis and treatment are very important for reducing the associated high mortality risks.

The commercial UAT (Alere BinaxNOW® Legionella Urinary Antigen Card) is an immunochromatographic membrane assay that is used to detect the Legionella pneumophila serogroup 1 soluble antigen in human urine.16 A vast majority of community‐acquired LP cases are caused by this species and serogroup.4, 17, 18 Although it is very useful to define a diagnosis of LP, it is of limited use to detect non‐serogroup 1 L. pneumophila and other species. The sensitivity and specificity of UAT for detecting other serogroups and species are currently unknown.

LAMP (Loopamp Legionella Detection Kit E) is a nucleic acid amplification method19 to specifically amplify the target gene using four primers specific to six distinct regions. The whole amplification reaction continuously takes place under isothermal conditions. We used this method to support our legionellosis diagnosis. The sensitivity and specificity of this method are 91.3% (21/23) and 100% (112/112), respectively.20 The correlation between UAT, LAMP, and culture tests is shown in Table 2; almost all patients (21/22) with positive cultures tested positive for LP via LAMP, while only 59.1% of patients (13/22) with positive cultures tested positive for LP via a UAT.19 We hypothesized that the cause of this case of LP was non‐serogroup 1 L. pneumophila infection or an infection from another species, because the positive results were obtained using the LAMP method, and negative results were observed using the UAT.

Table 2.

Correlation between UAT, LAMP, and culture tests19

UAT LAMP
+ Total + Total
Culture + 13 9 22 21 1 22
0 113 113 0 113 113
13 122 135 21 114 135

Inhalation or ingestion of potting soil is associated with LP. We identified several cases of legionellosis with causes related to gardening (see Table 3). While a few patients were infected by L. pneumophila, most patients were infected by L. longbeachae. This species was first isolated in 1980 from a patient with pneumonia in Long Beach, California.21 Interestingly, the UAT was negative for all patients infected with L. Longbeachae. We also assembled data regarding the distribution of Legionella species in Japanese potting soils (see Table 4). Similar reports have been published for distribution in other areas such as America, Australia, and Europe.22, 23 These reports consistently indicate that that L. pneumophila is not commonly found in the soil. Therefore, we should consider other Legionella species as the causative pathogen particularly when the soil is the possible pathway of infection, as in this case. Although we were not able to identify which Legionella species was the pathogen in this case, we speculated it was L. longbeachae or other related species and not L. pneumophila, because this patient was a gardener. This speculation explains both the negative result with the UAT and the positive result of the LAMP test.

Table 3.

Legionella cases caused by gardening

Time Nation Character Outcome UAT Species References
1996/7 Japan 52, m Death L. longbeachae 24
1999/7 Japan 83, m Survive L. longbeachae 25
2000/5 USA 77, f L. longbeachae 22
2000/5 USA 45, m Death L. longbeachae
2000/6 USA 46, f L. longbeachae
2000/8 Netherlands 81, m Death L. longbeachae 26
2000/8 Netherlands 69, m Death L. longbeachae
2004/12 Netherlands 67, m Death L. longbeachae
2001/5 Australia 40s, m Survive + L. pneumophila 27
2004/8 Japan 72, m Survive L. longbeachae 28
2009/10 Japan 74, m Survive L. longbeachae 29
Not noted New Zealand 79, f Death L. longbeachae 30
Not noted Switzerland 60, m + L. pneumophila 31

Table 4.

Legionella species occurring in Japanese compost

References:32 References:24
L. bozemanii 9 13
L. longbeachae 8 9
L. micdadei 5 7
L. pneumophila 2 1
L. cincinnatiensis 1 2
L. birminghamensis 1 1
L. gormanii 1 1
L. oakridgensis 0 2
L. spp.(cannot identify) 4 8
Legionella positive 16 22
Sample size 17 30

L. pneumophila is not the main species found in compost.

In conclusion, the medical history and clinical findings are key to diagnosing LP, because the UAT is not always helpful owing to its limited sensitivity. In particular, when gardening is the route of infection, because the occurrence of L. pneumophila in the soil is rare, other species such as L. longbeachae should be considered as the potential causative pathogen for LP. In addition, in such cases, the clinicians should be careful in interpreting the result of the UAT, because the results can be negative even when these species are present. The LAMP test is useful with higher sensitivity and specificity than UAT when the clinical suspicion of legionellosis is high although UAT is negative.

Conflict of Interest

The authors have stated explicitly that there are no conflicts of interest in connection with this article.

Miyata J, Huh JY, Ito Y, Kobuchi T, Kusukawa K, Hayashi H. Can we truly rely on the urinary antigen test for the diagnosis? Legionella case report. J Gen Fam Med. 2017;18:139–143. https://doi.org/10.1002/jgf2.16

References

  • 1. Fang GD, Fine M, Orloff J, et al. New and emerging etiologies for community‐acquired pneumonia with implications for therapy. A prospective multicenter study of 359 cases. Medicine (Baltimore). 1990;69:307. [DOI] [PubMed] [Google Scholar]
  • 2. Bartlett JG, Mundy LM. Community‐acquired pneumonia. N Engl J Med. 1995;333:1618. [DOI] [PubMed] [Google Scholar]
  • 3. Marston BJ, Plouffe JF, File TM Jr, et al. Incidence of community‐acquired pneumonia requiring hospitalization. Results of a population‐based active surveillance Study in Ohio. The Community‐Based Pneumonia Incidence Study Group. Arch Intern Med. 1997;157:1709. [PubMed] [Google Scholar]
  • 4. von Baum H, Ewig S, Marre R, et al. Community‐acquired Legionella pneumonia: new insights from the German competence network for community acquired pneumonia. Clin Infect Dis. 2008;46:1356. [DOI] [PubMed] [Google Scholar]
  • 5. Cunha BA, Burillo A, Bouza E. Legionnaires’ disease. Lancet. 2015;387:376–85. [DOI] [PubMed] [Google Scholar]
  • 6. Kirby BD, Snyder KM, Meyer RD, Finegold SM. Legionnaires’ disease: report of sixty‐five nosocomially acquired cases of review of the literature. Medicine (Baltimore). 1980;59:188. [PubMed] [Google Scholar]
  • 7. Mulazimoglu L, Yu VL. Can Legionnaires disease be diagnosed by clinical criteria? A critical review Chest 2001;120:1049. [DOI] [PubMed] [Google Scholar]
  • 8. Yu VL, Kroboth FJ, Shonnard J, et al. Legionnaires’ disease: new clinical perspective from a prospective pneumonia study. Am J Med. 1982;73:357. [PubMed] [Google Scholar]
  • 9. Cunha BA, Pherez FM, Nouri Y. Legionella community‐acquired pneumonia (CAP) presenting with spontaneous bilateral pneumothoraces. Heart Lung. 2008;37:238–41. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10. Garcia MC, Ebeo CT, Byrd RP Jr, Roy TM. Rhabdomyolysis associated with pneumococcal pneumonia: an early clinical indicator of increased morbidity? Tenn Med. 2002;95:67–9. [PubMed] [Google Scholar]
  • 11. Fraser DW, Tsai TR, Orenstein W, et al. Legionnaires’ disease: description of an epidemic of pneumonia. N Engl J Med. 1977;297:1189. [DOI] [PubMed] [Google Scholar]
  • 12. Benin AL, Benson RF, Besser RE. Trends in legionnaires disease, 1980‐1998: declining mortality and new patterns of diagnosis. Clin Infect Dis. 2002;35:1039. [DOI] [PubMed] [Google Scholar]
  • 13. Fernández JA, López P, Orozco D, Merino J. Clinical study of an outbreak of Legionnaire's disease in Alcoy, Southeastern Spain. Eur J Clin Microbiol Infect Dis. 2002;21:729. [DOI] [PubMed] [Google Scholar]
  • 14. Blázquez Garrido RM, Espinosa Parra FJ, Alemany Francés L, et al. Antimicrobial chemotherapy for Legionnaires disease: levofloxacin versus macrolides. Clin Infect Dis. 2005;40:800. [DOI] [PubMed] [Google Scholar]
  • 15. Mykietiuk A, Carratalà J, Fernández‐Sabé N, et al. Clinical outcomes for hospitalized patients with Legionella pneumonia in the antigenuria era: the influence of levofloxacin therapy. Clin Infect Dis. 2005;40:794. [DOI] [PubMed] [Google Scholar]
  • 16. Alere Scarborough, Inc. Package insert of Alere BinaxNOW® Legionella Urinary Antigen Card Rev. 6 (January 2013).
  • 17. Yu VL, Plouffe JF, Pastoris MC, et al. Distribution of Legionella species and serogroups isolated by culture in patients with sporadic community‐acquired legionellosis: an international collaborative survey. J Infect Dis. 2002;186:127. [DOI] [PubMed] [Google Scholar]
  • 18. Helbig JH, Uldum SA, Bernander S, et al. Clinical utility of urinary antigen detection for diagnosis of community‐acquired, travel‐associated, and nosocomial legionnaires’ disease. J Clin Microbiol. 2003;41:838. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Eiken Chemical Co. Ltd, Japan. Product information of Loopamp Legionella Detection Kit E. Rev. March 2013.
  • 20. Yamaguchi K, Tateda K, Nakamori Y, et al. LAMP hou wo mochiita Mycoplasma pneumoniae to Legionella spp. ni yoru kokyuki kansenshou no jinsoku shindan shiyaku no hyouka. [The LAMP method assessment of the rapid diagnostic test reagent for Mycoplasma pneumoniae and Legionella app.]. Jpn J Med Pharm Sci. 58, No 4, 565–71. Article in Japanese. [Google Scholar]
  • 21. McKinney RM, Porschen RK, Edelstein PH, et al. Legionella longbeachae species nova, another etiologic agent of human pneumonia. Ann Intern Med. 1981;94:739–43. [DOI] [PubMed] [Google Scholar]
  • 22. Centers for Disease Control and Prevention (CDC) . Legionnaires’ Disease associated with potting soil–California, Oregon, and Washington, May‐June 2000. MMWR Morb Mortal Wkly Rep. 2000;49:777–8. [PubMed] [Google Scholar]
  • 23. Casati S, Conza L, Bruin J, Gaia V. Compost facilities as a reservoir of Legionella pneumophila and other Legionella species. Clin Microbiol Infect. 2010;16:945–7. [DOI] [PubMed] [Google Scholar]
  • 24. Koide M, Arakaki N, Saito A. Distribution of Legionella longbeachae and other legionellae in Japanese potting soils. J Infect Chemother. 2001;7:224–7. [DOI] [PubMed] [Google Scholar]
  • 25. Suzuki K, Tachibana A, Hatakeyama S, Yamaguchi K, Tateda K. Clinical characteristics in 8 sporadic cases of community‐acquired Legionella pneumonia. Nihon Kokyuki Gakkai Zasshi. 2002;40:282–6. [PubMed] [Google Scholar]
  • 26. den Boer JW, Yzerman EP, Jansen R, et al. Legionnaires’ disease and gardening. Clin Microbiol Infect. 2007;13:88–91. [DOI] [PubMed] [Google Scholar]
  • 27. Wallis L, Robinson P. Soil as a source of Legionella pneumophila serogroup 1 (Lp1). Aust N Z J Public Health. 2005;29:518–20. [DOI] [PubMed] [Google Scholar]
  • 28. Kubota M, Tomii K, Tachikawa R, et al. Legionella longbeachae pneumonia infection from home garden soil. Nihon Kokyuki Gakkai Zasshi. 2007;45:698–703. [PubMed] [Google Scholar]
  • 29. Shinohara Y, Takabe K. Nougyou juujisha ni okeru Legionella haien (toku ni Legionella longbeachae) no kikensei ni tsuite. [Risk of Legionella pneumoniae infection (especially due to Legionella longbeachae) among agricultural workers.]. Kyosai Examiner's Report. 2011;29:29–40. Article in Japanese. [Google Scholar]
  • 30. Kingston M, Padwell A. Fatal legionellosis from gardening. N Z Med J. 1994;107:111. [PubMed] [Google Scholar]
  • 31. Piso RJ, Caruso A, Nebiker M. Hose as a source of Legionella pneumonia. A new risk factor for gardeners? J Hosp Infect 2007;67:396–7. Epub 2007 Nov 19. [DOI] [PubMed] [Google Scholar]
  • 32. Koide M, Saito A, Okazaki M, Umeda B, Benson RF. Isolation of Legionella longbeachae serogroup 1 from potting soils in Japan. Clin Infect Dis. 1999;29:943–4. [DOI] [PubMed] [Google Scholar]

Articles from Journal of General and Family Medicine are provided here courtesy of Wiley

RESOURCES