Table 6.
Reliability of radiomic features through reconstruction algorithms RA using ICC (3DRP is excluded)
| Type | Feature | ICC | 95% UCI | 95% LCI | Precision |
|---|---|---|---|---|---|
| Local | IDM | 0.94 | 0.80 | 0.98 | ±9% |
| ID | 0.97 | 0.90 | 0.99 | ±4.5% | |
| IMC 2 | 0.77 | 0.45 | 0.89 | ±22% | |
| Meanb | 0.83 | 0.79 | 0.94 | ±6.5% | |
| Entropya | 0.84 | 0.68 | 0.96 | ±14% | |
| Summation entropya | 0.84 | 0.70 | 0.96 | ±13% | |
| Difference entropya | 0.78 | 0.76 | 0.95 | ±9.5% | |
| Regional | RPC | 0.90 | 0.74 | 0.97 | ±11.5% |
| LRE | 0.73 | 0.65 | 0.80 | ±7.5% | |
| SRE | 0.82 | 0.73 | 0.94 | ±10.5% |
ID, IDM, Inverse Difference, and Inverse Difference Moment; IMC1,2.: Information Correlation Method 1 and 2; RPC, Run Percentage; SRE, Short Run Emphasis.
Corrected for GL dependence.
Corrected for GL and volume dependence.