Table 2.
Percentage deviation in GTV dose metrics between the static and moving target for SABR lung treatments with a 5s motion period. Deviations were calculated based on simulation of a single fraction delivery, and for the total number of fractions delivered for a treatment.
| Target Motion Amplitude (mm) | Single Fraction | All Fractions | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| D99% | D50% | D1% | D99% | D50% | D1% | |||||||
| VMAT | 5 |
|
|
|
0.0 |
|
|
|||||
| 10 | 2.6 |
|
|
3.0 |
|
|
||||||
| 20 |
|
1.5 | 3.7 |
|
1.4 | 4.9 | ||||||
| 30 |
|
1.3 | 7.8 |
|
1.1 | 7.9 | ||||||
| dMLC IMRT | 5 |
|
1.0 |
|
|
0.9 |
|
|||||
| 10 | 0.3 | 0.0 |
|
0.4 | 0.0 |
|
||||||
| 20 |
|
1.6 | 5.5 |
|
1.9 | 5.4 | ||||||
| 30 |
|
2.0 | 5.3 |
|
2.1 | 5.0 | ||||||
| 3D CRT | 5 | 0.8 | 0.2 |
|
0.7 | 0.2 |
|
|||||
| 10 | 0.2 |
|
0.4 | 0.1 |
|
|
||||||
| 20 | 1.1 | 0.4 |
|
1.1 | 0.4 |
|
||||||