Dye penetration depth in millimeters (indicative of microleakage) in the three groups

Composite Margin Mean (μm) Minimum (μm) Maximum (μm) Std. deviation
Bulk-fill (3M) Gingival 523.40 0.00 1508.00 543.50
Occlusal 93.80 0.00 808.00 214.17
Bulk-fill (SonicFill) Gingival 290.25 0.00 860.00 343.07
Occlusal 127.35 0.00 1254.00 302.04
Conventional (Z250) Gingival 590.20 0.00 1498.00 597.78
Occlusal 145.45 0.00 507.00 199.14