Skip to main content
Biomedical Optics Express logoLink to Biomedical Optics Express
. 2017 Oct 16;8(11):5039. doi: 10.1364/BOE.8.005039

In vivo study of optical speckle decorrelation time across depths in the mouse brain: erratum

Muhammad Mohsin Qureshi 1,4, Joshua Brake 2,4, Hee-Jae Jeon 1, Haowen Ruan 2, Yan Liu 2, Abdul Mohaimen Safi 1, Tae Joong Eom 3, Changhuei Yang 2, Euiheon Chung 1,*
PMCID: PMC5695950  PMID: 29188100

Abstract

We correct values listed in the main text of our recent paper: [Biomed. Opt. Express 8(11), 4855 (2017)].

OCIS codes: (030.6140) Speckle, (170.3660) Light propagation in tissues, (170.7050) Turbid media


The last sentence of the 2nd paragraph of section “4. Results” should read

“The respective mean decorrelation times for 1.1, 1.8, 2.5, and 3.2 mm depth of point-like source are 5.3, 1.5, 0.37, and 0.26 ms, with standard deviations of 4.8, 1.6, 0.16, 0.13 ms.”

instead of the version in the manuscript (copied below) which contains incorrect values.

“The respective mean decorrelation times for 1.1, 1.8, 2.5, and 3.2 mm depth of point-like source are 7.5, 3.5, 1.1, and 0.6 ms, with standard deviations of 5.9, 2.4, 0.6, and 0.3 ms.”