Table 5. Large studies of airway stents for treatment of central airway obstruction.

Trial/Study design/Intervention Retrospective review Airway stenting for benign or malignant tracheobronchial obstruction Stent type Outcomes Complications
Seven-Year Experience with the Dumon Prosthesis (101) (N=1,058, 677 malignant), total number of stents placed 1,574 Silicone Not clearly defined All complications 335/309 (21.2%);
stent migration 9.5%;
occlusion from secretions 3.6%;
granuloma formation 7.9%
Airway Stenting for Malignant and Benign Tracheobronchial Stenosis (102) (N=143, 96 malignant), total number of procedures 309 Retrospective review of cases collected in prospective patient database Airway stenting or stent revision for benign or malignant tracheobronchial obstruction Silicone 182 (87%), metallic 27 (13%) 95% with symptom improvement overall All complications 131/309 (42%);
stent migration 5.2%;
occlusion from secretions 27.2%;
occlusion from granulation tissue 8.7%;
airway perforation 1.3%
Outcomes of Tracheobronchial Stents in Patients with Malignant Airway Disease (103) (N=172, all malignant) Retrospective review Airway stenting for malignant tracheobronchial obstruction 166 SEMS, 6 rigid metal Not reported All complications: 23/172 (13.3%);
stent migration 2.9%;
tumor ingrowth 5.2%;
excessive granulation 4.1%;
restenosis 1.2%
Respiratory Infections Increase the Risk of Granulation Tissue Formation Following Airway Stenting in Patients With Malignant Airway Obstruction (104) (N=172, all malignant) Retrospective cohort study Airway stenting for malignant tracheobronchial obstruction Silicone=46, SEMS=149 Not reported Not reported

Rates expressed as events per stent day: infection rates (Ultraflex: 0.00477, Aero: 0.01259, Dumon Tube: 0.00393, Y: Dumon 0.00762); migrations rates (Ultraflex: 0.00116, Aero: 0.00278, Dumon Tube: 0.00467, Dumon Y: 0); granulation rates (Ultraflex: 0.00135, Aero: 0.00328, Dumon Tube: 0.00368, Dumon Y: 0.00537); mucous plugging (Ultraflex: 0.00188, Aero: 0.00498, Dumon Tube: 0.00464, Dumon Y: 0.00373); stent fracture (Ultraflex: 0.00022, Aero: 0.000054, Dumon Tube: 0, Dumon Y: 0).