Skip to main content
. 2017 Nov 21;7:15946. doi: 10.1038/s41598-017-16290-9

Table 2.

Coefficient of variation (CV) for intra-assay and inter-assaya.

Samples Intra-assay precision Inter-assay precision
Measured concentration (ng/mL) CV (%) Measured concentration (ng/mL) CV (%)
A 46.6 ± 3.0 6.4 ± 0.4 49.1 ± 2.7 5.6 ± 0.3
B 24.1 ± 2.3 9.5 ± 0.9 23.8 ± 1.8 7.6 ± 0.6
C 11.9 ± 1.0 8.5 ± 0.7 12.3 ± 1.0 7.9 ± 0.6

aIntra-assay precision was calculated from four independent experiments of the same assay on a single day but at different time points, while inter-assay precision was calculated from the assay repeated on three different days (n = 3). All the assays were carried out in triplicate. Data are expressed as mean ± SD (standard deviation). CV: Coefficient of variation.