Assay No of Samples Tested Positive Detections HBV-DNA PCR Positive (False +ve)
Comparison between CLIA Murex Assay and SD Bioline Rapid
CLIA 1500 58 58 NIL
Rapid 1500 27 17 10
Comparison between CLIA Murex Assay and ELISA Kit
CLIA 1500 32 32 NIL
ELISA 1500 20 14 06
Comparison between CLIA Murex Assay and ARCHITECT SYSTEM
CLIA 1500 33 33 NIL
ARCHITECT 1500 30 30 NIL