Skip to main content
. 2001 Aug 31;1:4. doi: 10.1186/1471-2210-1-4

Table 3.

Effects of cumulative doses of risperidone on urodynamic and EMG parameters in anesthetized rats. Values are Mean ± S.E.M.

Urodynamic parameters EUS EMG parameters


Dose BC (ml) MV (ml) RV (%) PT PP CT (sec) ET (sec) HFO Phase 1 Phase 2 Phase 3 Burst
(mg/kg) (mm Hg) (mm Hg) (mm Hg) (%) (%) (%) Amp.
(%)
Control 0.35 0.27 21 2.4 11.5 18.5 3.6 1.6 100 100 100 100
(±0.097) (±0.072) (±5.6) (±0.62) (±0.95) (±1.43) (±0.83) (±0.19)
0.01 0.38 0.17 47** 2.8 11.7 19.3 2.7 1.3 100 76 91 (±8.4) 105
(±0.080) (±0.033) (±9.2) (±0.72) (±1.0) (±1.97) (±0.49) (±0.12) (±11.5) (±14.7) (±3.4)
0.1 0.38 0.10* 70** 3.4 11.7 19.4 1.5** 1.0* 84 50* 78* 80
(±0.055) (±0.019) (±7.8) (±0.44) (±0.82) (±1.94) (±0.34) (±0.22) (±11.7) (±12.3) (±10.1) (±19.6)
1 0.40 0.12** 67** 5.0* 12.4 18.6 1.4** 0.9** 74 47* 68** 76
(±0.060) (±0.016) (±5.8) (±1.02) (±1.16) (±2.6) (±0.35) (±0.18) (±13.2) (±12.7) (±8.0) (±14.0)
10 0.54 0.19 60** 5.8** 13.7** 17.2 2.2* 1.1* 81 71 (±22) 73** 84
(±0.080) (±0.036) (±7.7) (±1.02) (±1.34) (±0.96) (±0.46) (±0.22) (±15.2) (±9.0) (±14.6)
*

* p < 0.05; ** p < 0.01