Table 3. Antigen capture ELISA in urine samples.

Sample Code Serology qPCR Ag ELISA OD (plasma)* Ag ELISA result (Plasma) Ag ELISA OD (Urine) Ag ELISA result (urine)
018R Pos Pos 0.4516 Pos 0.7164 Pos
074R Pos Pos 0.6831 Pos 1.1876 Pos
080R Pos Pos 0.5941 Pos 0.5934 Pos
094R Neg Neg 0.3638 Neg 0.2033 Neg
098R Neg Neg 0.4138 Neg 0.1198 Neg
V001 Neg Neg 0.3300 Neg 0.4135 Neg
V002 Neg Neg 0.2381 Neg 0.3506 Neg
V003 Neg Neg 0.2993 Neg 0.3240 Neg
099R Pos Neg 0.6465 Pos 2.0799 Pos

Antigen capture ELISA was performed as describe in the text. The cut off values (mean plus two standard deviations) were 0.3816 for serum samples; 0.4395 for plasma samples; and 0.5195 for urine samples.