Table 3. Antigen capture ELISA in urine samples.
Sample Code | Serology | qPCR | Ag ELISA OD (plasma)* | Ag ELISA result (Plasma) | Ag ELISA OD (Urine) | Ag ELISA result (urine) |
---|---|---|---|---|---|---|
018R | Pos | Pos | 0.4516 | Pos | 0.7164 | Pos |
074R | Pos | Pos | 0.6831 | Pos | 1.1876 | Pos |
080R | Pos | Pos | 0.5941 | Pos | 0.5934 | Pos |
094R | Neg | Neg | 0.3638 | Neg | 0.2033 | Neg |
098R | Neg | Neg | 0.4138 | Neg | 0.1198 | Neg |
V001 | Neg | Neg | 0.3300 | Neg | 0.4135 | Neg |
V002 | Neg | Neg | 0.2381 | Neg | 0.3506 | Neg |
V003 | Neg | Neg | 0.2993 | Neg | 0.3240 | Neg |
099R | Pos | Neg | 0.6465 | Pos | 2.0799 | Pos |
Antigen capture ELISA was performed as describe in the text. The cut off values (mean plus two standard deviations) were 0.3816 for serum samples; 0.4395 for plasma samples; and 0.5195 for urine samples.
*Antigen capture ELISA for samples code V001—V003 were performed using serum samples and were obtained from volunteer individuals. Ag ELISA = antigen capture ELISA, OD = optical density, Pos = positive, Neg = negative.