Table 5.

Reproducibility of Tinnitus Functional Index (TFI) scores: Intra-class correlations (ICC) and limits of agreement between two administrations. The TFI showed excellent stability over time as indicated by the high ICC values and acceptable test-retest agreement. Although most of the subscales were below 95% limits of agreement, it only suggested marginal measurement error. The smallest detectable change scores for the global TFI and subscales are comparable to the limits of agreement. ICC = Intra-class correlations; Mean diff = the mean difference scores between the repeated measure; SEM = Standard error of measurement; SDC = Smallest detectable change.

N = 44 Mean (±SD) Reliability Agreement




Scale Baseline Retest ICC (95%CI) Mean diff SEM SDC Limits of agreement % of agreement
Tinnitus Functional index 45.3 (±20.1)  45.6(±19.4) 0.91 (0.84–0.95)   −0.3    8.1 22.4 22.2–22.7 93.2%
Intrusiveness 57.1 (±19.1) 58.8 (±21.3) 0.92 (0.82–0.96)   −1.7    7.6 21.1 19.4–22.7 93.2%
Sense of control 58.1 (±22.8) 57.6 (±20.9) 0.81 (0.65–0.90)     0.5  12.5 34.8 35.3–34.2 95.5%
Cognitive 39.2 (±38.2) 41.9 (±24.3) 0.89 (0.79–0.94)   −2.6  11.8 32.8 30.2–35.5 93.2%
Sleep 41.9 (±31.6) 41.2 (±30.1) 0.91 (0.83–0.95)     0.7  12.8 35.5 36.2–34.8 93.2%
Auditory 33.9 (±29.7) 36.1 (±30.2) 0.95 (0.90–0.97)   −2.3    9.6 26.6 24.3–28.9 93.2%
Relaxation 64.6 (±25.9) 62.9 (±25.3) 0.83 (0.69–0.91)     1.7  13.9 38.5 40.3–36.8 88.6%
Quality of life 35.1 (±26.1) 34.0 (±24.6) 0.86 (0.75–0.92)     1.1  12.6 34.9 36.0–33.8 93.2%
Emotional 36.0 (±28.1) 36.6 (±27.5) 0.87 (0.77–0.93)   −0.6  13.3 36.8 36.2–37.4 91.0%