Table 2.
Summary of the 40 scenarios for which the stoichiometric calibration was conducted
| Test | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 3‐par fit | 2‐par fit | Plugs / Materials | Phantom Material | Phantom Width (cm) | Plug Hole | Slice Thickness (mm) | Weighted |
|
|
| 1a | 1b | G, W | water | 30 | center | 3 | x | nominal | |
| 2a | 2b | G, W | water | 30 | center | 3 | x | calculated | |
| 3a | 3b | G, W | water | 30 | center | 1.5 | x | nominal | |
| 4a | 4b | G, W | water | 30 | inner | 3 | x | nominal | |
| 5a | 5b | G, W | water | 30 | outer | 3 | x | nominal | |
| 6a | 6b | G, W | water | 40 | center | 3 | x | nominal | |
| 7a | 7b | G, W | water | 40 | inner | 3 | x | nominal | |
| 8a | 8b | G, W | water | 40 | outer | 3 | x | nominal | |
| 9a | 9b | G | solid water | 33 | distributed | 3 | x | nominal | |
| 10a | 10b | G, W | water | 30 | center | 3 | × | nominal | |
| 11a | 11b | C, W | water | 30 | center | 3 | × | nominal | |
| 12a | 12b | C, W | water | 30 | center | 3 | × | nominal | |
| 13a | 13b | G, C, W | water | 30 | center | 3 | x | nominal | |
| 14a | 14b | G, C, W | water | 30 | center | 3 | × | nominal | |
| 15a | 15b | G, W, Al | water | 30 | center | 3 | x | nominal | |
| 16a | 16b | G, W, Al | water | 30 | center | 3 | × | nominal | |
| 17a | 17b | C, W, Al | water | 30 | center | 3 | x | nominal | |
| 18a | 18b | C, W, Al | water | 30 | center | 3 | × | nominal | |
| 19a | 19b | G, C, W, Al | water | 30 | center | 3 | x | nominal | |
| 20a | 20b | G, C, W, Al | water | 30 | center | 3 | × | nominal | |
; ; , .