Skip to main content
. 2017 Aug 30;118(6):2991–3006. doi: 10.1152/jn.00384.2017

Table 1.

VsEP latency, amplitude, and threshold before and after different doses of XE991 and saline

XE991
VsEPs 50 mg/kg (5, 3) 25 mg/kg (6) 12.5 mg/kg (5) 5 mg/kg (6) 3.5 mg/kg (6) 2.5 mg/kg (5) 1 mg/kg (5) 0.5 mg/kg (5) 0.05 mg/kg (5) Saline
(5)
Latency, µs
P1
    Baseline 1,375 ± 49 1,336 ± 55 1,354 ± 24 1,327 ± 58 1,347 ± 41 1,330 ± 68 1,356 ± 34 1,325 ± 54 1,264 ± 56 1,337 ± 68
    0–20 min 1,531 ± 101 1,412 ± 41 1,459 ± 43 1,371 ± 66 1,353 ± 59 1,306 ± 65 1,313 ± 40 1,315 ± 55 1,258 ± 56 1,338 ± 78
    25–40 min 1,655 ± 51 1,580 ± 36 1,627 ± 24 1,512 ± 77 1,449 ± 73 1,318 ± 58 1,275 ± 38 1,276 ± 50 1,245 ± 52 1,338 ± 83
    45–60 min 1,640 ± 59 1,585 ± 38 1,632 ± 26 1,519 ± 85 1,462 ± 45 1,351 ± 60 1,268 ± 30 1,265 ± 40 1,238 ± 61 1,326 ± 84
N1
    Baseline 1,701 ± 82 1,629 ± 59 1,662 ± 18 1,610 ± 82 1,651 ± 48 1,624 ± 55 1,639 ± 27 1,626 ± 47 1,572 ± 30 1,639 ± 791
    0–20 min 1,856 ± 144 1,706 ± 39 1,768 ± 53 1,662 ± 89 1,643 ± 62 1,590 ± 61 1,599 ± 19 1,604 ± 50 1,567 ± 30 1,643 ± 90
    25–40 min 1,957 ± 23 1,939 ± 65 1,959 ± 28 1,844 ± 88 1,773 ± 51 1,585 ± 70 1,569 ± 35 1,562 ± 41 1,536 ± 45 1,637 ± 97
    45–60 min 1,943 ± 46 1,935 ± 60 1,963 ± 23 1,848 ± 84 1,780 ± 45 1,631 ± 66 1,566 ± 47 1,550 ± 36 1,524 ± 44 1,625 ± 95
P2ab
    Baseline 2,069 ± 41 1,973 ± 81 2,090 ± 41 2,072 ± 86 2,023 ± 72 2,032 ± 67 2,046 ± 64 1,988 ± 24 1,915 ± 38 2,015 ± 80
    0–20 min 2,358 ± 110 2,164 ± 94 2,265 ± 84 2,188 ± 104 2,133 ± 71 2,047 ± 83 2,060 ± 62 1,966 ± 44 1,919 ± 31 2,008 ± 84
    25–40 min 2,572 ± 33 2,526 ± 204 2,511 ± 164 2,465 ± 101 2,357 ± 75 2,161 ± 62 2,164 ± 48 2,006 ± 56 1,926 ± 35 2,003 ± 92
    45–60 min 2,572 ± 24 2,536 ± 183 2,523 ± 167 2,457 ± 78 2,381 ± 94 2,257 ± 89 2,207 ± 39 2,042 ± 34 1,935 ± 36 1,999 ± 96
Amplitude, µV
P1N1
    Baseline 0.93 ± 0.22 0.81 ± 0.15 1.01 ± 0.29 0.97 ± 0.15 0.97 ± 0.18 1.01 ± 0.21 0.89 ± 0.24 1.02 ± 0.17 0.89 ± 0.16 0.84 ± 0.16
    0–20 min 0.63 ± 0.17 0.69 ± 0.14 0.79 ± 0.14 0.86 ± 0.14 0.96 ± 0.12 1.08 ± 0.18 0.94 ± 0.26 1.05 ± 0.14 0.91 ± 0.22 0.86 ± 0.17
    25–40 min 0.33 ± 0.06 0.38 ± 0.13 0.50 ± 0.13 0.61 ± 0.17 0.80 ± 0.14 1.18 ± 0.23 1.06 ± 0.32 1.12 ± 0.14 0.96 ± 0.19 0.87 ± 0.15
    45–60 min 0.31 ± 0.06 0.45 ± 0.15 0.56 ± 0.14 0.31 ± 0.06 0.87 ± 0.11 1.15 ± 0.23 1.11 ± 0.26 1.16 ± 0.21 1.03 ± 0.22 0.86 ± 0.20
P2abN1
    Baseline 0.68 ± 0.23 0.65 ± 0.15 0.94 ± 0.21 0.91 ± 0.33 0.91 ± 0.20 0.74 ± 0.17 0.79 ± 0.12 0.83 ± 0.18 0.78 ± 0.23 1.10 ± 0.46
    0–20 min 0.52 ± 0.22 0.66 ± 0.12 0.75 ± 0.33 0.99 ± 0.42 1.07 ± 0.16 0.89 ± 0.14 1.05 ± 0.28 0.96 ± 0.12 0.85 ± 0.28 1.06 ± 0.45
    25–40 min 0.52 ± 0.24 0.46 ± 0.24 0.31 ± 0.21 0.62 ± 0.27 0.97 ± 0.27 1.03 ± 0.17 1.27 ± 0.32 1.03 ± 0.16 0.85 ± 0.27 1.05 ± 0.51
    45–60 min 0.52 ± 0.27 0.43 ± 0.21 0.31 ± 0.16 0.58 ± 0.27 0.95 ± 0.29 1.14 ± 0.18 1.27 ± 0.34 1.04 ± 0.16 0.95 ± 0.28 1.08 ± 0.49
Threshold, dB re:1 g/ms
    Baseline −9.9 ± 1.3 −10.5 ± 1.9 −11.1 ± 1.3 −10.5 ± 0.0 −10.0 ± 1.2 −9.3 ± 1.6 −11.1 ± 1.3 −9.9 ± 2.5 −8.7 ± 1.6 −9.9 ± 1.3
    0–20 min −3.5 ± 1.7 −3.0 ± 4.1 −3.3 ± 1.6 −5.0 ± 2.3 −8.5 ± 3.6 −11.1 ± 1.3 −12.3 ± 1.6 −10.5 ± 2.1 −9.3 ± 1.6 −9.3 ± 1.6
    25–40 min −1.5 ± 0.0 −4.0 ± 2.3 −3.3 ± 2.7 −5.0 ± 2.3 −7.0 ± 2.3 −9.9 ± 1.3 −11.7 ± 2.78 −11.1 ± 2.5 −10.5 ± 0.0 −9.9 ± 1.3
    45–60 min −1.5 ± 3.0 −4.0 ± 3.0 −3.9 ± 3.3 −6.0 ± 1.6 −7.5 ± 1.9 −9.3 ± 1.6 −12.3 ± 1.6 −12.3 ± 1.6 −8.7 ± 1.6 −9.3 ± 1.6

Values are means ± SD of vestibular response (VsEP) latency, amplitude, and threshold over a period of 60 min following a 20-min stable baseline period for each of 9 different XE991 doses and saline; sample size (n) is indicated in parentheses for each group. Each 20-min period was an average of 4–5 consecutive measurements ~5 min apart. In the 50 mg/kg dose group, responses were essentially eliminated following XE991 administration in 2 animals. All mice were anesthetized with urethane-xylazine and monitored with rectal and brain temperature probes throughout the experiments. Stimulus level was +6 dB re: 1.0 g/ms for latency and amplitude measurements. The latency for P2 is represented as P2ab = (P2a + P2b)/2, which defined a composite value for P2 when in bifed form of P2a and P2b.