The information of the 12 MOS sensors.

Sensors Labels Sensor Name Target Gases Typical Detection Range
S1 TGS826 Ammonia 30–300 ppm
S2 TGS822 Alcohol, Solvent vapors 50–5000 ppm
S3 TGS816 Methane, Butane, Propane 500–10,000 ppm
S4 TGS813 Methane, Butane, Propane 500–10,000 ppm
S5 MQ138 Aldehydes, alcohols, ketones, aromatics 1 to 100 ppm
S6 MQ137 Ammonia 5–500 ppm
S7 TGS2620 Alcohol, Solvent vapors 50–5000 ppm
S8 TGS2611 Methane 1–25%
S9 TGS2610 Butane, Propane 1–25%
S10 TGS2603 Trimethylamine, methyl mercaptan 1–10 ppm
S11 TGS2602 VOCs, ammonia, hydrogen sulfide 1–30 ppm
S12 TGS2600 hydrogen, ethanol 1–30 ppm