Skip to main content
. 2013 Jan 7;14(1):176–191. doi: 10.1120/jacmp.v14i1.4052

Table 3.

Some of the IMRT objectives set for the first optimization for HN.6.

ROI Name Objective Type Dose (cGy) Weight
CTV56 Minimum dose 5700 100
CTV63 Minimum dose 6350 100
CTV70 Minimum dose 7100 10
modPTV70 Maximum dose 7690 100
modPTV70 Minimum dose 7000 65
optPTV63 Maximum dose 6720 70
optPTV63 Minimum dose 6450 80
optPTV63_m Uniform dose 6550 5
optPTV56 Minimum dose 5700 100
optPTV56_m Maximum dose 6125 100
optPTV56_m Uniform dose 5650 1
PTV56 Minimum dose 2800 1
PTV63 Minimum dose 3200 1
PTV70 Minimum dose 3000 30
brainstem Maximum dose 5000 100
brainstem_prv Maximum dose 5500 33
cord Maximum dose 4000 100
cord_prv Maximum dose 4500 70
mandible Maximum dose 7000 100
lt_parotid_opt Maximum EUD 2350 20
ring50 Maximum dose 5000 10
ring56 Maximum dose 5600 100
ring63 Maximum dose 6300 50
ring70 Maximum dose 7000 100