Table 4.
Change in lumpectomy cavity volume | ||||||||
---|---|---|---|---|---|---|---|---|
First Author, year | N | Treatment | Imaging Technique | Surgical Clips | Before RT a | During RT a | Correlated with time from surgery | Correlated with initial LC volume |
Vicini, 20037 | 18 | PBI | CT | Yes | NR | Yes | NR | NR |
Weed, 20045 | 28 | 17 PBI, 11 WBI | CT | Yes | NR | Yes b | Ye s c | NR |
Jacobson, 20068 | 20 | WBI | CT | No | NR | Yes | NR | Yes |
Oh, 20069 | 30 | WBI | CT | Yes | NR | Yes | Yes c | Ye s |
Kader, 20082 | 205 | PBI | CT | No | Yes | NR | Yes c | NR |
Hurkmans, 200910 | 10 | WBI | CT | Yes | NR | Yes | Yes c | NR |
Harris, 200911 | 11 | WBI | CT, PI | Yes | Yes | Yes | NR | NR |
Hepel, 200912 | 30 | WBI | CT | Yes d | NR | Yes | Yes c | Ye s |
Prendergast, 200913 | 36 | 30 WBI, 6 PBI | CT | Yes | Yes | Yes | Yes | Yes |
Tersteeg, 200914 | 77 | WBI | CT | Yes d | NR | Yes | NR | Yes |
Sharma, 200915 | 24 | WBI | CT | Yes d | NR | Yes | Yes c | NR |
Flannery, 200916 | 43 | WBI | CT | Yes d | NR | Yes | Yes | Yes |
Yang, 201017 | 102 | WBI | CT, CBCT |e | No | NR | Yes | Yes c | Ye s |
Yang, 201018 | 19 | WBI | CT, CBCT | No | NR | Yes | NR | NR |
Kim, 201019 | 13 | PBI | CT | Yes d | Yes | NR | NR | NR |
Present Study | 26 | 20 WBI, 6 PBI | CT, CBCT | Yes | Yes | Yes | Yes | Yes |
Before RT refers to period of LC change assessment where a second imaging scan was performed before the start of RT while during RT refers to time period where a second imaging scan was performed during or at end of RT.
Second CT was performed just before, during or day of completion of treatment.
An inverse relationship was observed between time from surgery and change in LC volume.
Clips were used when available.
10 patients underwent multiple CBCT scans during RT and data was analyzed to assess correlation between CT and CBCT scans for seroma contouring.
; ; ; ; ; ; ; ; .