Skip to main content
. 2013 Sep 6;14(5):127–139. doi: 10.1120/jacmp.v14i5.4316

Table 3.

Refitted parameters for PBC, AAA, and CC with PB as a reference. Results for the RS model

RS Refitted for Treatment Type
D50±1SE
Y±1SE
s
Seppenwoolde et al. (1) (paired lungs): 34 0.9 0.06
PBC Lung
33.89±0.20
0.902±0.006
0.06
Paired lungs AAA Lung
32.02±0.29
0.893±0.009
0.06
CC Lung
31.21±0.19
0.892±0.006
0.06
PBC LGL
34.60±0.17
0.897±0.001
0.06
Paired lungs AAA LGL
32.45±0.25
0.900±0.002
0.06
CC LGL
30.74±0.15
0.900±0.001
0.06
PBC Tang
33.16±0.15
0.899±0.000
0.06
Paired lungs AAA Tang
31.00±0.23
0.900±0.001
0.06
CC Tang
29.58±0.23
0.902±0.001
0.06
Gagliardi et al. (2) (ipsilateral lung) 30.1 0.966 0.012
refitted for CCa (Brink et al (7) , PB ref)
26.20±0.40
0.972±0.005
0.012
PBC LGL
30.49±0.13
0.959±0.003
0.012
Ipsilateral lung AAA LGL
29.23±0.19
0.966±0.004
0.012
CC LGL
27.57±0.12
0.964±0.003
0.012
PBC Tang
29.50±0.15
0.962±0.001
0.012
Ipsilateral lung AAA Tang
27.52±0.17
0.974±0.001
0.012
CC Tang
26.16±0.18
0.973±0.001
0.012
Rancati et al. (3) (ipsilateral lung) 17.30 1.07 0.11
PBC LGL
17.34±0.06
1.053±0.016
0.11
Ipsilateral lung AAA LGL
16.55±0.11
1.053±0.027
0.11
CC LGL
15.62±0.09
1.049±0.022
0.11
PBC Tang
16.92±0.09
1.058±0.004
0.11
Ipsilateral lung AAA Tang
15.70±0.08
1.092±0.004
0.11
CC Tang
14.97±0.09
1.092±0.005
0.11
a

Collapsed cone The standard errors presented refer to the mathematical uncertainties that stem from the refitting procedure.