Skip to main content
. 2013 Nov 4;14(6):155–166. doi: 10.1120/jacmp.v14i6.4328

Table 1.

The details of delivery configuration for each case and plan type used in this study, and in general, at our institution. “E‐comp” refers to electronic compensation. For multiple cranial metastases, we typically now use four nonaxial arcs

Fraction Case Type Rx Dose (Gy) Fraction Size (Gy) 6 MV flat DMLC 600 MU/min 6 MV FFF DMLC 1400 MU/min 6 MV FFF VMAT 1400 MU/min 10 MV FFF DMLC 2400 MU/min 10 MV FFF VMAT 2400 MU/min
Conventional Meningioma 54 1.8 7 field nonaxial 7 field nonaxial 2 nonaxial arcs 7 field nonaxial 2 nonaxial arcs
Breast Tangents 45 1.8 Tangents w/e‐comp Tangents w/e‐comp n/a Tangents w/e‐comp n/a
Cervix w/Elective Pelvic Nodes 50.4 1.8 7 field axial 7 field axial 2 axial arcs 7 field axial 2 axial arcs
Lung 70 2 4 axial beams 4 axial beams 1 arc 4 axial beams 1 arc
Prostate 70 2 5 field axial 5 field axial 1 arc 5 field axial 1 arc
Head and Neck 70 2 9 field axial 9 field axial 2 axial arcs 9 field axial 2 axial arcs
Hypo Partial breast 38.5 3.85 4 field nonaxial 4 field nonaxial 2 axial arcs 4 field nonaxial 2 axial arcs
Radiosurgery Spine SBRT 16 16 7 field fan 7 field fan 2 axial arcs 7 field fan 2 axial arcs
Triple Cranial Metastasis 18,18,&16 18,18,&16 9 field axial 9 field axial 2 axial arc 9 field axial 2 axial arcs
Cranial Metastasis 18 18 7 field nonaxial 7 field nonaxial 3 nonaxial arcs 7 field nonaxial 3 nonaxial arcs
Lung SBRT 60 20 13 field nonaxial 13 field nonaxial 2 axial arcs 13 field nonaxial 2 axial arcs