Table 1.

Summary of the results from fluorescence spectroscopy, atomic force microscopy, and photoacoustic spectroscopy experiments. Values are represented as mean ± standard deviation (n = 5 for fluorescent spectroscopy, n = 100 for atomic force microscopy (AFM), and n = 5 for photoacoustic spectroscopy (PAS)).

10 min 30 min

Fluor-T30-SWNT T30-SWNT Fluor-T30-SWNT T30-SWNT

Quenching efficiency Outer diameters [nm] Length [nm] PA signal [V] wavelength 941 nm Quenching efficiency Outer diameters [nm] Length [nm] PA signal [V] wavelength 941 nm
Probe 60% 98% ±0.72% 5.2 ±2.8 937 ±580 0.69 ±0.028 98% ±0.83% 7.9 ±4.1 1093 ±714 0.60 ±0.024
Probe 20% 47% ±38% 2.0 ±1.1 648 ±568 2.13 ±0.11 69% ±33% 2.0 ±1.1 588 ±504 1.39 ±0.068
Bath 74% ±13% 2.5 ±2.0 707 ±524 0.99 ±0.045 99% ±1.4% 1.8 ±0.74 617 ±504 0.69 ±0.028
No sonication 16% ±9.5% - - - 23.% ±14% - - -