Skip to main content
. 2017 Oct 5;55(6):521–528. doi: 10.2486/indhealth.2017-0120
Type Woven

Sample No. 1 2 3 4 5

Fail ratio in splash test (by visual inspection) (21.3 kPa) 5/5 5/5 0/5 3/5 3/5

Fail ratio in splash test (using absorption paper) (21.3 kPa) 5/5 5/5 5/5 5/5 5/5

Leakage volume by the quantitative splash test Large Large Small Small Small

Protective performance classification by the pressurized cell test (JIS T 8060) <Class 1 <Class 1 Class 1 <Class 1 Class 1