Skip to main content
. 2010 Jan 28;11(1):77–87. doi: 10.1120/jacmp.v11i1.3042

Table 1.

Minimum, maximum, and mean doses for different organs at risk using 3D CRT and HT plans.

Minimum Dose (Gy) Maximum Dose (Gy) Mean Dose (Gy)
3D CRT HT 3D CRT HT 3D CRT HT
Right Breast 0.80 3.32 21.95 20.47 9.85 7.72
Left Breast 1.46 4.42 22.22 21.67 14 11.19
Liver 0 0.38 21.98 21.76 10.5 7.2
Heart 12.63 7.48 22.27 21.17 16.44 11.38
Lung 11.06 7.52 22.35 21.99 16.22 12.91
Thyroid 18.23 8.52 21.94 21.67 21.15 16.34
Larynx 7.58 5.77 20.94 12.19 12 8.25
Vertebral Body 1.48 0.35 22.26 20.69 14.72 9.61
Spinal Cord 1.52 0.35 22.26 20.69 14.72 9.61
Right Kidney 1.35 0.40 7.94 5.48 3.33 2.18
Left Kidney 1.52 0.39 13.43 5.7 4.42 2.3
Right Shoulder 1.17 0.92 1.85 4.20 1.38 1.47
Left Shoulder 1.25 4.39 17 18.59 2.71 8.74