Table 4. Diagnostic value of four energy spectrum parameters in the diagnosis of metastatic lymph nodes.
Parameters | Youden index | AUC | Cut-off value | Sensitivity (%) | Specificity (%) | Accuracy (%) |
---|---|---|---|---|---|---|
IC | 0.745 | 0.928 | >2.56 | 83.3 | 91.2 | 85.3 |
NIC | 0.726 | 0.875 | >0.289 | 96.1. | 76.5 | 91.2 |
Spectral curve slope | 0.706 | 0.907 | >2.692 | 88.2 | 82.4 | 86.8 |
AUC, area under the curve; IC, iodine concentration; NIC, normalized iodine concentration.