Skip to main content
. 2017 Dec 5;21:2331216517743887. doi: 10.1177/2331216517743887

Table 5.

Multiple Regression Analyses for Preoperative Prediction of SIN Performance of CI Users (n = 20) at 1 Year or More Post CI Activation.

Predictor B SE p R2 change R 2
Model with LA
 dHL 0.09 0.04 .022 .215 .37
 LA 1.87 0.94 .065 .155
Model with LDT
 dHL 0.09 0.04 .026 .238 .37
 LDT 0.01 0.01 .082 .128
Model with RSpan
 dHL 0.08 0.03 .013 .238 .55
 RSpan −0.22 0.06 .003 .314

Note. Separate regression analyses were performed for LA, LDT, and RSpan after controlling for duration of hearing loss. SIN = sentences-in-noise test; CI = cochlear implant; dHL = duration of hearing loss; LA = lexical access; LDT = lexical-decision test; RSpan = Reading Span test.; B = unstandardized regression coefficient; SE = standard error; p = level of significance; R2 = proportion of variance.