Skip to main content
. 2017 Fall;12(4):468–473. doi: 10.22037/iej.v12i4.17494

Table 2.

Mean values and Standard Deviation of the Preparation time (sec), the number of cycles for each instrumentation (NCI), Time to instruments failure(sec), the number of cycles to failure (NCF) and the sum of NCI and NCF (n=10

Preparation time NCI Time to failure NCF NCI+NCF
PDL 64.55 (5.04)a 376.59 (29.43) 182.07 (94.42)b 910.37 (472.10)b 1286.96 (488.40)b
PDR 102.65 (58.71)b 513.28 (293.57) 152.38 (97.95)b 761.93 (489.75)b 1275.21 (685.86)b
WOG 96.72 (25.71)b 483.61 (128.57) 52.95 (61.08)a 264.76 (305.42)a 748.37 (364.31)a

There were statistical differences between groups and were marked with different letters in the table